Design and Development of Flex Sensor-Based Respiratory Rate Monitoring System Using Node MCU ESP32

Flex sensors are used to measure a patient’s breathing status such as Eupnea, Bradypnea, and Tachypnea, providing respiratory rate data. The main objective of this capstone is to design and develop a device that accurately measures respiratory rate, thereby improving patient care assessment. The system utilized a flex sensor that can accurately detect the expansion and contraction of the chest and abdomen during breathing. This sensor is then used to calculate the respiratory rate, which is displayed in real-time on both the OLED screen and the web server. The OLED screen provides offline monitoring, allowing the respiratory rate and status to be easily viewed in realtime. On the other hand, the web server provides a more comprehensive view of the respiratory rate data, including a graphical representation of the start and end of each breath. The system has demonstrated an accuracy rate of 90.18% in eupnea and 91.03% in tachypnea, with a total accuracy of 93.73%, which is considered very satisfactory. The belt is more efficient when placed on the abdomen compared to the chest, which had an accuracy rate of 91.44% and 89.13%, and an overall efficiency rate of 90.29% and is interpreted as very satisfactory. This Flex Sensor-Based Respiratory Rate Monitoring System provides a reliable method for measuring respiratory rate, allowing medical personnel to obtain accurate baseline data for assessing a patient’s respiratory function. The high accuracy rate aids in informed decision-making, enhancing patient care practices and leading to better health outcomes.

Authors

Institutions

Publication Details

Journal
QCU The Star
Published
2024-12-13
DOI
https://doi.org/10.64807/avz6yr41
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Development of Flex Sensor-Based Respiratory Rate Monitoring System Using Node MCU ESP32

Maria Beatriz Mamado, Justine Jay Baldomar, Carl John Calimpusan, Nikki Dolor et al.
QCU The Star
Non-Invasive Vital Sign Monitoring
article

Design and Development of Flex Sensor-Based Respiratory Rate Monitoring System Using Node MCU ESP32

Maria Beatriz Mamado, Justine Jay Baldomar, Carl John Calimpusan, Nikki Dolor, John Keneth Labian
article en

Abstract

Flex sensors are used to measure a patient’s breathing status such as Eupnea, Bradypnea, and Tachypnea, providing respiratory rate data. The main objective of this capstone is to design and develop a device that accurately measures respiratory rate, thereby improving patient care assessment. The system utilized a flex sensor that can accurately detect the expansion and contraction of the chest and abdomen during breathing. This sensor is then used to calculate the respiratory rate, which is displayed in real-time on both the OLED screen and the web server. The OLED screen provides offline monitoring, allowing the respiratory rate and status to be easily viewed in realtime. On the other hand, the web server provides a more comprehensive view of the respiratory rate data, including a graphical representation of the start and end of each breath. The system has demonstrated an accuracy rate of 90.18% in eupnea and 91.03% in tachypnea, with a total accuracy of 93.73%, which is considered very satisfactory. The belt is more efficient when placed on the abdomen compared to the chest, which had an accuracy rate of 91.44% and 89.13%, and an overall efficiency rate of 90.29% and is interpreted as very satisfactory. This Flex Sensor-Based Respiratory Rate Monitoring System provides a reliable method for measuring respiratory rate, allowing medical personnel to obtain accurate baseline data for assessing a patient’s respiratory function. The high accuracy rate aids in informed decision-making, enhancing patient care practices and leading to better health outcomes.

QCU The StarVol. 2(1)
Quezon City University (PH)
Openalex Percentile: Top 74%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Development of Flex Sensor-Based Respiratory Rate Monitoring System Using Node MCU ESP32 — Maria Beatriz Mamado, Justine Jay Baldomar, et al. · QCU The Star (2024) | TGRS Research Map | TGRS