Tacrolimus (FK-506) levels determined by 2 different chemiluminescence immunoassay-based analytical methods: A comparative cross-sectional study

Several assays have been used to monitor tacrolimus levels. Automated immunoassay systems are preferred routinely because of their simplicity and rapid turnaround times. However, variations in the measured results for the same sample by different assays necessitate the evaluation of various immunoassay systems for consistency. This study aimed to compare whole-blood tacrolimus concentrations measured using 2 different chemiluminescence analytical methods: chemiluminescent microparticle immunoassay (CMIA; Abbott Diagnostics) and chemiluminescent immunoassay (CLIA; Snibe Diagnostics). A total of 257 patients who had undergone kidney transplantation were included in this study. Whole-blood tacrolimus concentrations were measured using the MAGLUMI 800 analyzer and compared with the ARCHITECT i1000SR analyzer using correlation analysis and Bland-Altman plots. There was a strong correlation between tacrolimus concentrations measured using MAGLUMI and those measured using ARCHITECT (R = 0.916, P < .001). An intraclass correlation coefficient (ICC) value of 0.934 (CI = 0.915-0.949) indicated excellent reliability of the measurements. Comparison of samples with a routine ARCHITECT assay for tacrolimus showed a minimal bias of 0.385 ng/mL (95% CI = 4.46%-3.69%), but scattering analysis indicated that the method agreed when the tacrolimus levels were low but disagreed at high levels. Overall, the measured tacrolimus level in patient samples was higher by MAGLUMI than by ARCHITECT with a median difference of 0.17 ng/mL and a median percentage difference of 3.4% respectively. Snibe MAGLUMI is a reliable assay with excellent correlation, but a small positive bias against Abbott ARCHITECT in measuring whole-blood tacrolimus levels. This bias is most likely due to the cross-reactivity of the metabolites in the Snibe MAGLUMI platform.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2025-09-26
DOI
https://doi.org/10.1097/md.0000000000044895
Primary Topic
Renal Transplantation Outcomes and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tacrolimus (FK-506) levels determined by 2 different chemiluminescence immunoassay-based analytical methods: A comparative cross-sectional study

Prakash Pokhrel, Aseem Bhattarai, Raju Kumar Dubey, Anuradha Kadel et al.
Medicine
Renal Transplantation Outcomes and Treatments
article

Tacrolimus (FK-506) levels determined by 2 different chemiluminescence immunoassay-based analytical methods: A comparative cross-sectional study

Prakash Pokhrel, Aseem Bhattarai, Raju Kumar Dubey, Anuradha Kadel, Nikita Kharal, Eans Tara Tuladhar, Srijana Sapkota, Apeksha Niraula, Vijay Kumar Sharma, Mithileshwer Raut
article en

Abstract

Several assays have been used to monitor tacrolimus levels. Automated immunoassay systems are preferred routinely because of their simplicity and rapid turnaround times. However, variations in the measured results for the same sample by different assays necessitate the evaluation of various immunoassay systems for consistency. This study aimed to compare whole-blood tacrolimus concentrations measured using 2 different chemiluminescence analytical methods: chemiluminescent microparticle immunoassay (CMIA; Abbott Diagnostics) and chemiluminescent immunoassay (CLIA; Snibe Diagnostics). A total of 257 patients who had undergone kidney transplantation were included in this study. Whole-blood tacrolimus concentrations were measured using the MAGLUMI 800 analyzer and compared with the ARCHITECT i1000SR analyzer using correlation analysis and Bland-Altman plots. There was a strong correlation between tacrolimus concentrations measured using MAGLUMI and those measured using ARCHITECT (R = 0.916, P < .001). An intraclass correlation coefficient (ICC) value of 0.934 (CI = 0.915-0.949) indicated excellent reliability of the measurements. Comparison of samples with a routine ARCHITECT assay for tacrolimus showed a minimal bias of 0.385 ng/mL (95% CI = 4.46%-3.69%), but scattering analysis indicated that the method agreed when the tacrolimus levels were low but disagreed at high levels. Overall, the measured tacrolimus level in patient samples was higher by MAGLUMI than by ARCHITECT with a median difference of 0.17 ng/mL and a median percentage difference of 3.4% respectively. Snibe MAGLUMI is a reliable assay with excellent correlation, but a small positive bias against Abbott ARCHITECT in measuring whole-blood tacrolimus levels. This bias is most likely due to the cross-reactivity of the metabolites in the Snibe MAGLUMI platform.

MedicineVol. 104(39)
Tribhuvan University Teaching Hospital (NP)
Openalex Percentile: Top 57%
Renal Transplantation Outcomes and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.