DAC®, a Hyaluronan Derivative in the Form of a Gel, Is Effective in Preventing Periprosthetic Joint Infection During Arthroplasty Revision in Patients with Comorbidities: A Retrospective, Observational, 1:1-Matched Case–Control Clinical Investigation

<b>Background/Objectives</b>: Joint arthroplasty revision and comorbidities are considered two increased risk factors for periprosthetic joint infection (PJI), a complication that may lead to prolonged hospital stay, continued antibiotic therapy, and serious consequences, including amputation and, in extreme cases, death of the patient. DAC<sup>®</sup> is an absorbable barrier in the form of a gel that, when applied as a coating, protects implants from bacterial colonization. The aim of this case-control study was to explore whether the device could decrease the risk of PJI in a cohort of patients who underwent arthroplasty revision and were affected by comorbidities. <b>Methods</b>: We carried out a retrospective 1:1-matched case-control investigation in 96 patients who underwent arthroplasty revision between January 2023 and December 2024; these patients had at least 6 months of follow-up, had comorbidities, and were treated with DAC<sup>®</sup> gel. The control group consisted of 96 subjects who received standard of care. Demographics, comorbidities, type of arthroplasty, adverse event onset, and incidence of PJI were recorded for all patients. <b>Results</b>: No significant differences in relevant demographics, type of arthroplasty revision, or number or type of comorbidities, except for smoking, were observed between the two groups. At 6-month follow-up, no PJIs were recorded in the DAC<sup>®</sup> treatment group, whereas five (5.2%) PJIs were observed in the control group (<i>p</i> = 0.0235). No adverse event or impairment of implant osseointegration related to the use of DAC<sup>®</sup> was observed. <b>Conclusions</b>: The DAC<sup>®</sup> bioabsorbable hydrogel acts as a physical barrier when applied over an arthroplasty revision implant, protecting it from bacterial adhesion and preventing biofilm formation.

Authors

Institutions

Publication Details

Journal
Biomedicines
Published
2025-09-30
DOI
https://doi.org/10.3390/biomedicines13102408
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DAC®, a Hyaluronan Derivative in the Form of a Gel, Is Effective in Preventing Periprosthetic Joint Infection During Arthroplasty Revision in Patients with Comorbidities: A Retrospective, Observational, 1:1-Matched Case–Control Clinical Investigation

Germano Giuliani, Raffaele Quitadamo, Costantino Stigliani, Giuseppe Ricciardi et al.
Biomedicines
Total Knee Arthroplasty Outcomes
article

DAC®, a Hyaluronan Derivative in the Form of a Gel, Is Effective in Preventing Periprosthetic Joint Infection During Arthroplasty Revision in Patients with Comorbidities: A Retrospective, Observational, 1:1-Matched Case–Control Clinical Investigation

Germano Giuliani, Raffaele Quitadamo, Costantino Stigliani, Giuseppe Ricciardi, Ancona A. Armando, Rosario Demita
article en

Abstract

<b>Background/Objectives</b>: Joint arthroplasty revision and comorbidities are considered two increased risk factors for periprosthetic joint infection (PJI), a complication that may lead to prolonged hospital stay, continued antibiotic therapy, and serious consequences, including amputation and, in extreme cases, death of the patient. DAC<sup>®</sup> is an absorbable barrier in the form of a gel that, when applied as a coating, protects implants from bacterial colonization. The aim of this case-control study was to explore whether the device could decrease the risk of PJI in a cohort of patients who underwent arthroplasty revision and were affected by comorbidities. <b>Methods</b>: We carried out a retrospective 1:1-matched case-control investigation in 96 patients who underwent arthroplasty revision between January 2023 and December 2024; these patients had at least 6 months of follow-up, had comorbidities, and were treated with DAC<sup>®</sup> gel. The control group consisted of 96 subjects who received standard of care. Demographics, comorbidities, type of arthroplasty, adverse event onset, and incidence of PJI were recorded for all patients. <b>Results</b>: No significant differences in relevant demographics, type of arthroplasty revision, or number or type of comorbidities, except for smoking, were observed between the two groups. At 6-month follow-up, no PJIs were recorded in the DAC<sup>®</sup> treatment group, whereas five (5.2%) PJIs were observed in the control group (<i>p</i> = 0.0235). No adverse event or impairment of implant osseointegration related to the use of DAC<sup>®</sup> was observed. <b>Conclusions</b>: The DAC<sup>®</sup> bioabsorbable hydrogel acts as a physical barrier when applied over an arthroplasty revision implant, protecting it from bacterial adhesion and preventing biofilm formation.

BiomedicinesVol. 13(10)
Hospital Madre Teresa (BR)
Openalex Percentile: Top 57%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.