Wavelength Calibration for an External Cavity Diode Laser Using a Polynomial Dual-Cosine Model

A polynomial dual-cosine model is proposed for the wavelength calibration of an ECDL (Santec-TSL710-O-band). An analysis of the ECDL’s measured spectral data demonstrates that the polynomial dual-cosine model reduces the relative wavenumber fitting residuals by a factor of five within a scanning range of 30 cm−1. The experimental results of broadband temperature measurement (700~1600 K) in the tube furnace confirm that the proposed model successfully reduces the maximum temperature relative error from 6.7% to 2.3%. The wavelength calibration model effectively promotes further research on the broadband absorption spectroscopy thermometry method and its application in the temperature diagnostics of aeroengine combustors.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2025-09-29
DOI
https://doi.org/10.3390/photonics12100964
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wavelength Calibration for an External Cavity Diode Laser Using a Polynomial Dual-Cosine Model

Ruifeng Kan, C. T. Chen, Wenqiang Xing, Zhongqiang Yu et al.
Photonics
Spectroscopy and Laser Applications
article

Wavelength Calibration for an External Cavity Diode Laser Using a Polynomial Dual-Cosine Model

Ruifeng Kan, C. T. Chen, Wenqiang Xing, Zhongqiang Yu, Dingfeng Shi, An Huang, Sen Ai, Zhenyu Xu, Rantong Niu, Cheng Du
article en

Abstract

A polynomial dual-cosine model is proposed for the wavelength calibration of an ECDL (Santec-TSL710-O-band). An analysis of the ECDL’s measured spectral data demonstrates that the polynomial dual-cosine model reduces the relative wavenumber fitting residuals by a factor of five within a scanning range of 30 cm−1. The experimental results of broadband temperature measurement (700~1600 K) in the tube furnace confirm that the proposed model successfully reduces the maximum temperature relative error from 6.7% to 2.3%. The wavelength calibration model effectively promotes further research on the broadband absorption spectroscopy thermometry method and its application in the temperature diagnostics of aeroengine combustors.

PhotonicsVol. 12(10)
University of Science and Technology of China (CN), Chinese Academy of Sciences (CN), Hefei Institutes of Physical Science (CN), Anhui Institute of Optics and Fine Mechanics (CN)
Openalex Percentile: Top 75%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Wavelength Calibration for an External Cavity Diode Laser Using a Polynomial Dual-Cosine Model — Ruifeng Kan, C. T. Chen, et al. · Photonics (2025) | TGRS Research Map | TGRS