Validation and reliability of mechanical stiffness assessment tools in multilayered polyurethane phantom models of healthy and diabetic plantar soft tissues

Plantar soft tissue stiffness plays a crucial role in the development of diabetic foot complications, but in vivo assessments are constrained by anatomical variability and probe-induced measurement artifacts. To develop anatomically layered polyurethane phantom models mimicking healthy and diabetic plantar soft tissues and evaluate the reliability and concurrent validity of four mechanical stiffness assessment tools, [MyotonPRO, Shore Durometer, IndentoPRO, and Tissue Compliance Meter (TCM)] against Shear Wave Elastography (SWE). Six regional phantom models (calcaneus, midfoot, forefoot) with skin, fat pad, fascia, and muscle layers were fabricated. SWE was performed in no-contact mode to eliminate surface compression, improving measurement consistency. A total of 162 configurations were tested under blinded and randomized conditions. Intra- and inter-rater reliability was assessed using ICCs; concurrent validity was evaluated via correlation and regression analyses with SWE. All devices demonstrated excellent reliability (ICC range: 0.88-0.99). SWE-derived stiffness was significantly higher in diabetic models, especially in the calcaneal and midfoot regions (p < 0.001). IndentoPRO showed the highest correlation with SWE (r = 0.91), followed by MyotonPRO (r = 0.87), TCM (r = 0.85), and Durometer (r = 0.78). TCM exhibited the highest predictive value (R<sup>2</sup> = 0.502) and most consistent performance across diabetic regions. The developed phantom models offer a standardized platform for evaluating stiffness assessment tools. While SWE remains the reference standard, mechanical devices, particularly TCM and IndentoPRO, demonstrated valid and reproducible performance. This phantom-based approach holds promise for supporting medical device development, regulatory validation, and preclinical testing in diabetic foot biomechanics.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-09-30
DOI
https://doi.org/10.1038/s41598-025-21084-5
Primary Topic
Diabetic Foot Ulcer Assessment and Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation and reliability of mechanical stiffness assessment tools in multilayered polyurethane phantom models of healthy and diabetic plantar soft tissues

Robert Schleip, Thomas Horstmann, Wolfgang Bauermeister, Tülay Çevik Saldıran et al.
Scientific Reports
Diabetic Foot Ulcer Assessment and Management
article

Validation and reliability of mechanical stiffness assessment tools in multilayered polyurethane phantom models of healthy and diabetic plantar soft tissues

Robert Schleip, Thomas Horstmann, Wolfgang Bauermeister, Tülay Çevik Saldıran, Katja Bartsch, Torsten Pohl
article en

Abstract

Plantar soft tissue stiffness plays a crucial role in the development of diabetic foot complications, but in vivo assessments are constrained by anatomical variability and probe-induced measurement artifacts. To develop anatomically layered polyurethane phantom models mimicking healthy and diabetic plantar soft tissues and evaluate the reliability and concurrent validity of four mechanical stiffness assessment tools, [MyotonPRO, Shore Durometer, IndentoPRO, and Tissue Compliance Meter (TCM)] against Shear Wave Elastography (SWE). Six regional phantom models (calcaneus, midfoot, forefoot) with skin, fat pad, fascia, and muscle layers were fabricated. SWE was performed in no-contact mode to eliminate surface compression, improving measurement consistency. A total of 162 configurations were tested under blinded and randomized conditions. Intra- and inter-rater reliability was assessed using ICCs; concurrent validity was evaluated via correlation and regression analyses with SWE. All devices demonstrated excellent reliability (ICC range: 0.88-0.99). SWE-derived stiffness was significantly higher in diabetic models, especially in the calcaneal and midfoot regions (p < 0.001). IndentoPRO showed the highest correlation with SWE (r = 0.91), followed by MyotonPRO (r = 0.87), TCM (r = 0.85), and Durometer (r = 0.78). TCM exhibited the highest predictive value (R<sup>2</sup> = 0.502) and most consistent performance across diabetic regions. The developed phantom models offer a standardized platform for evaluating stiffness assessment tools. While SWE remains the reference standard, mechanical devices, particularly TCM and IndentoPRO, demonstrated valid and reproducible performance. This phantom-based approach holds promise for supporting medical device development, regulatory validation, and preclinical testing in diabetic foot biomechanics.

Scientific ReportsVol. 15(1)
Bitlis Eren University (TR), Diploma Hochschule (DE), Technical University of Munich (DE), Kharkiv National Medical University (UA)
Technische Universität München
Openalex Percentile: Top 64%
Diabetic Foot Ulcer Assessment and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.