Interactions Between Grounding Systems and Buried Conductive Objects

This paper addresses the critical challenge of accurately predicting the performance and safety of intentional grounding grids in the presence of nearby passive conductors under fault conditions. Traditional single-grid models often neglect the influence of unintentional conductive elements, such as adjacent grounding meshes or buried metallic pipes, which can lead to significant underestimation of touch-voltage hazards and ground-impedance variations. To overcome these limitations, a coupled circuit-field approach based on the use of Green's functions is developed. This methodology enables simultaneous computation of self- and mutual-impedance parameters and detailed mapping of ground-potential distributions in three carefully chosen configurations: (1) an isolated <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$36 \mathrm{m} \times 36 \mathrm{m}$</tex> m mesh, (2) two floating but adjacent grounding grids at variable separations, and (3) two grounding grids with a 15 cm diameter buried pipe traversing both fenced areas. Numerical simulations demonstrate that passive conductors can reduce overall ground impedance by up to 5% and generate normalized touch-voltages as high as 0.5 p.u. between the primary grid and the pipe. These findings prove that extraneous conductors provide unintended current-dispersion paths and substantially alter ground-potential rise, thereby increasing risk to personnel. The results underscore the necessity of incorporating mutualcoupling effects into grounding-system design guidelines and suggest that targeted bonding or isolation measures can effectively mitigate transferred potentials. By enhancing modeling accuracy, this work establishes a foundation for improved safety standards and informs the development of robust design practices for complex industrial and utility grounding networks.

Authors

Institutions

Publication Details

Published
2025-07-15
DOI
https://doi.org/10.1109/eeeic/icpseurope64998.2025.11169134
Primary Topic
BIM and Construction Integration
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interactions Between Grounding Systems and Buried Conductive Objects

Massimo Mitolo, Erika Stracqualursi, Rodolfo Araneo
BIM and Construction Integration
article

Interactions Between Grounding Systems and Buried Conductive Objects

Massimo Mitolo, Erika Stracqualursi, Rodolfo Araneo
article en

Abstract

This paper addresses the critical challenge of accurately predicting the performance and safety of intentional grounding grids in the presence of nearby passive conductors under fault conditions. Traditional single-grid models often neglect the influence of unintentional conductive elements, such as adjacent grounding meshes or buried metallic pipes, which can lead to significant underestimation of touch-voltage hazards and ground-impedance variations. To overcome these limitations, a coupled circuit-field approach based on the use of Green's functions is developed. This methodology enables simultaneous computation of self- and mutual-impedance parameters and detailed mapping of ground-potential distributions in three carefully chosen configurations: (1) an isolated <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$36 \mathrm{m} \times 36 \mathrm{m}$</tex> m mesh, (2) two floating but adjacent grounding grids at variable separations, and (3) two grounding grids with a 15 cm diameter buried pipe traversing both fenced areas. Numerical simulations demonstrate that passive conductors can reduce overall ground impedance by up to 5% and generate normalized touch-voltages as high as 0.5 p.u. between the primary grid and the pipe. These findings prove that extraneous conductors provide unintended current-dispersion paths and substantially alter ground-potential rise, thereby increasing risk to personnel. The results underscore the necessity of incorporating mutualcoupling effects into grounding-system design guidelines and suggest that targeted bonding or isolation measures can effectively mitigate transferred potentials. By enhancing modeling accuracy, this work establishes a foundation for improved safety standards and informs the development of robust design practices for complex industrial and utility grounding networks.

Irvine Valley College (US), Sapienza University of Rome (IT)
Openalex Percentile: Top 71%
BIM and Construction Integration
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.