Evaluation of Overvoltages Stressing Insulating Down-Conductor Systems Due to Direct Lightning Strikes Using ATP-EMTP

Insulating down-conductors are utilized in electrically insulated lightning protection systems, LPS, to safely direct the lightning current to the earth, preventing dangerous sparking to conductive parts of the structure as well as damage caused by the flow of the lightning current. The protection afforded by a down-conductor system utilizing insulating downconductors depends upon the design of the air-termination system, that is, the number and positioning of the air terminals, as well as of the catenary wires. This study presents an evaluation of the overvoltages stressing insulating downconductor systems due to direct lightning strikes using ATPEMTP. Both partially and fully electrically insulated LPS of several designs are examined by considering direct negative first and subsequent lightning strokes. The lightning overvoltages stressing an insulating down-conductor are lower in a partially than a fully insulated LPS. A great reduction of both internal and external overvoltages is observed when the electrically insulated LPS utilizes multiple insulating down-conductors.

Authors

Institutions

Publication Details

Published
2025-07-15
DOI
https://doi.org/10.1109/eeeic/icpseurope64998.2025.11169116
Citations
1
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
1.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Overvoltages Stressing Insulating Down-Conductor Systems Due to Direct Lightning Strikes Using ATP-EMTP

Pantelis N. Mikropoulos, Petros P. Tsouris, Nikolaos D. Kokkinos, Thomas E. Tsovilis et al.
1 citations
Lightning and Electromagnetic Phenomena
1.15
article

Evaluation of Overvoltages Stressing Insulating Down-Conductor Systems Due to Direct Lightning Strikes Using ATP-EMTP

Pantelis N. Mikropoulos, Petros P. Tsouris, Nikolaos D. Kokkinos, Thomas E. Tsovilis, Pavlos K. Samaras
article en
1 citations

Abstract

Insulating down-conductors are utilized in electrically insulated lightning protection systems, LPS, to safely direct the lightning current to the earth, preventing dangerous sparking to conductive parts of the structure as well as damage caused by the flow of the lightning current. The protection afforded by a down-conductor system utilizing insulating downconductors depends upon the design of the air-termination system, that is, the number and positioning of the air terminals, as well as of the catenary wires. This study presents an evaluation of the overvoltages stressing insulating downconductor systems due to direct lightning strikes using ATPEMTP. Both partially and fully electrically insulated LPS of several designs are examined by considering direct negative first and subsequent lightning strokes. The lightning overvoltages stressing an insulating down-conductor are lower in a partially than a fully insulated LPS. A great reduction of both internal and external overvoltages is observed when the electrically insulated LPS utilizes multiple insulating down-conductors.

Aristotle University of Thessaloniki (GR), BPM (Greece) (GR)
Openalex Percentile: Top 16%
Lightning and Electromagnetic Phenomena
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.