Potassium solution Certified Reference Material production at Inmetro

This paper presents the production of a potassium solution Certified Reference Material (CRM), MRC 8757.0001. The CRM was produced by the formulation method, using a high-purity potassium chloride (KCl) certified for purity at Inmetro, in compliance with ISO 17034, ISO 33405, and internal standards. High-Performance Inductively Coupled Plasma Optical Emission Spectrometry (HP-ICP-OES) was used to assess the homogeneity, short-term stability (at 50 °C), and long-term stability (between 20 °C and 25 °C) of the CRM. The certified potassium mass fraction, with all masses corrected for air buoyancy, was (1002 ± 11) mg/kg, considering k = 2.02, at a 95 % confidence level. With both the formulation method as a characterisation strategy and HP-ICP-OES for certification studies, we achieved a 47 % reduction of the combined uncertainty when compared to previous procedures at Inmetro. This CRM supports Inmetro’s objective to address the demand for metrological traceability of Brazilian organizations.

Authors

Publication Details

Journal
ACTA IMEKO
Published
2025-09-23
DOI
https://doi.org/10.21014/actaimeko.v14i3.1974
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Potassium solution Certified Reference Material production at Inmetro

Ana Catalina Palacios Osorio, Marcelo Dominguez de Almeida, Rodrigo Caciano de Sena
ACTA IMEKO
Scientific Measurement and Uncertainty Evaluation
article

Potassium solution Certified Reference Material production at Inmetro

Ana Catalina Palacios Osorio, Marcelo Dominguez de Almeida, Rodrigo Caciano de Sena
article en

Abstract

This paper presents the production of a potassium solution Certified Reference Material (CRM), MRC 8757.0001. The CRM was produced by the formulation method, using a high-purity potassium chloride (KCl) certified for purity at Inmetro, in compliance with ISO 17034, ISO 33405, and internal standards. High-Performance Inductively Coupled Plasma Optical Emission Spectrometry (HP-ICP-OES) was used to assess the homogeneity, short-term stability (at 50 °C), and long-term stability (between 20 °C and 25 °C) of the CRM. The certified potassium mass fraction, with all masses corrected for air buoyancy, was (1002 ± 11) mg/kg, considering k = 2.02, at a 95 % confidence level. With both the formulation method as a characterisation strategy and HP-ICP-OES for certification studies, we achieved a 47 % reduction of the combined uncertainty when compared to previous procedures at Inmetro. This CRM supports Inmetro’s objective to address the demand for metrological traceability of Brazilian organizations.

ACTA IMEKOVol. 14(3)
Openalex Percentile: Top 74%
Scientific Measurement and Uncertainty Evaluation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.