TOPAS-based 4D Monte Carlo simulation of transit dose in esophageal HDR brachytherapy: a phantom study

<i>Objective.</i>Intraluminal high-dose-rate (HDR) brachytherapy is a well-established treatment modality for esophageal cancer, where a radioactive source moves through a catheter to deliver dose at discrete dwell positions. However, during the source's transit phase non-negligible dose may be delivered to surrounding healthy tissues. This study utilizes the time-dependent (4D) Monte Carlo (MC) simulation approach to quantify the transit dose to organs at risks (OARs) during esophageal brachytherapy using the TOPAS tool.<i>Approach.</i>A simplified yet anatomically representative male anthropomorphic phantom was modeled in TOPAS, incorporating key anatomical structures including the esophagus, trachea, spinal cord, pharynx, and other OARs. The motion of an Ir-192 HDR source was dynamically simulated through a brachytherapy catheter, with source acceleration and deceleration explicitly modeled to reflect clinical delivery. Focusing on a 6 cm tumor in the upper esophagus, absorbed doses were calculated under varying conditions: constant versus variable source speeds and differing numbers of dwell points, to evaluate the dosimetric impact of source motion.<i>Main results.</i>Compared to static simulations that neglect source movement, the inclusion of realistic source motion led to a substantial increase in dose to the tumor itself, up to 31%. Transit dose to OARs along the catheter path and those adjacent to the esophagus, such as the pre-pharyngeal region and pharynx, reached up to 11.7% of the tumor dose under variable speed profiles. These results reveal significant underestimation in static dose calculations, highlighting the importance of accounting for source motion.<i>Significance.</i>This study underscores the dosimetric importance of accounting for source transit in HDR brachytherapy and demonstrates the value of TOPAS's time-feature for conducting 4D MC simulations of realistic source motion. The findings indicate that transit dose can contribute substantially to overall dose distributions and should be considered in treatment planning, particularly for tumors situated in anatomically complex or radiosensitive regions.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-09-30
DOI
https://doi.org/10.1088/1361-6560/ae0dec
Citations
2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
3.77
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

TOPAS-based 4D Monte Carlo simulation of transit dose in esophageal HDR brachytherapy: a phantom study

Roya Boodaghi Malidarre, F. Moradi, H.A. Abdul-Rashid, Ali Taheri
2 citations
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
3.77
article

TOPAS-based 4D Monte Carlo simulation of transit dose in esophageal HDR brachytherapy: a phantom study

Roya Boodaghi Malidarre, F. Moradi, H.A. Abdul-Rashid, Ali Taheri
article en
2 citations

Abstract

<i>Objective.</i>Intraluminal high-dose-rate (HDR) brachytherapy is a well-established treatment modality for esophageal cancer, where a radioactive source moves through a catheter to deliver dose at discrete dwell positions. However, during the source's transit phase non-negligible dose may be delivered to surrounding healthy tissues. This study utilizes the time-dependent (4D) Monte Carlo (MC) simulation approach to quantify the transit dose to organs at risks (OARs) during esophageal brachytherapy using the TOPAS tool.<i>Approach.</i>A simplified yet anatomically representative male anthropomorphic phantom was modeled in TOPAS, incorporating key anatomical structures including the esophagus, trachea, spinal cord, pharynx, and other OARs. The motion of an Ir-192 HDR source was dynamically simulated through a brachytherapy catheter, with source acceleration and deceleration explicitly modeled to reflect clinical delivery. Focusing on a 6 cm tumor in the upper esophagus, absorbed doses were calculated under varying conditions: constant versus variable source speeds and differing numbers of dwell points, to evaluate the dosimetric impact of source motion.<i>Main results.</i>Compared to static simulations that neglect source movement, the inclusion of realistic source motion led to a substantial increase in dose to the tumor itself, up to 31%. Transit dose to OARs along the catheter path and those adjacent to the esophagus, such as the pre-pharyngeal region and pharynx, reached up to 11.7% of the tumor dose under variable speed profiles. These results reveal significant underestimation in static dose calculations, highlighting the importance of accounting for source motion.<i>Significance.</i>This study underscores the dosimetric importance of accounting for source transit in HDR brachytherapy and demonstrates the value of TOPAS's time-feature for conducting 4D MC simulations of realistic source motion. The findings indicate that transit dose can contribute substantially to overall dose distributions and should be considered in treatment planning, particularly for tumors situated in anatomically complex or radiosensitive regions.

Physics in Medicine and BiologyVol. 70(20)
TATI University College (MY), Ural Federal University (RU), Multimedia University (MY), University of Cyberjaya (MY), University of Malaya (MY), Institute of Physics and Technology (RU), Sunway University (MY)
Openalex Percentile: Top 6%
Advanced Radiotherapy Techniques
3.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.