Advanced cardiotoxicity profiling using field potential imaging with UHD-CMOS-MEA in human iPSC-derived cardiomyocytes

Accurate assessment of cardiotoxicity using human induced pluripotent stem cell (iPSC)-derived cardiomyocytes is critical for ensuring drug safety during preclinical development. However, existing in vitro methodologies predominantly focus on QT interval prolongation and arrhythmia risk, often lacking the capacity to capture the complex interplay among multiple ion channels or to detect early manifestations of chronic cardiotoxicity-both of which are essential for evaluating long-term cardiac safety. Moreover, reliable prediction of pharmacological mechanisms of action remains a significant challenge. In this study, we employed field potential imaging utilizing an ultra-high-density complementary metal-oxide-semiconductor microelectrode array (MEA) comprising 236,880 electrodes distributed across a 5.9 × 5.5 mm active area. With 91.9% surface coverage by 11 μm electrodes spaced at 0.25 μm, the platform achieves near single-cell resolution across the entire cardiomyocyte monolayer. This system enabled the extraction of high-resolution electrophysiological endpoints, including the number and spatial variability of excitation origins, conduction velocity, and propagation area-thereby extending the analytical capabilities beyond those of conventional MEAs. Pharmacological testing revealed compound-specific alterations: Isoproterenol increased excitation origins, mexiletine reduced conduction velocity, and E-4031 diminished propagation area. Although these agents are well characterized, their effects were visualized with unprecedented spatiotemporal resolution, reflecting their underlying mechanisms of action. Multivariate analysis incorporating both conventional and novel endpoints enabled accurate classification of mechanisms under acute conditions. Furthermore, chronic cardiotoxicity induced by low-dose doxorubicin (0.03 μM) was sensitively detected within 24 h-earlier and at lower concentrations than previously reported-based on significant reductions in conduction velocity and propagation area. Collectively, these findings establish a high-resolution, mechanism-aware framework for in vitro cardiotoxicity profiling, offering improved predictive accuracy by capturing multi-ion channel interactions, spatial conduction abnormalities, and early signs of chronic dysfunction.

Authors

Institutions

Publication Details

Journal
Toxicological Sciences
Published
2025-09-26
DOI
https://doi.org/10.1093/toxsci/kfaf134
Citations
1
Primary Topic
Integrated Circuits and Semiconductor Failure Analysis
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced cardiotoxicity profiling using field potential imaging with UHD-CMOS-MEA in human iPSC-derived cardiomyocytes

Tomohiko Taniguchi, Nami Nagafuku, Naoki Matsuda, Ikuro Suzuki et al.
1 citations
Toxicological Sciences
Integrated Circuits and Semiconductor Failure Analysis
0.73
article

Advanced cardiotoxicity profiling using field potential imaging with UHD-CMOS-MEA in human iPSC-derived cardiomyocytes

Tomohiko Taniguchi, Nami Nagafuku, Naoki Matsuda, Ikuro Suzuki, Kazuki Matsuda, Yusaku Matsushita, Norimasa Miyamoto, Takashi Yoshinaga, Yuto Ishibashi
article en
1 citations

Abstract

Accurate assessment of cardiotoxicity using human induced pluripotent stem cell (iPSC)-derived cardiomyocytes is critical for ensuring drug safety during preclinical development. However, existing in vitro methodologies predominantly focus on QT interval prolongation and arrhythmia risk, often lacking the capacity to capture the complex interplay among multiple ion channels or to detect early manifestations of chronic cardiotoxicity-both of which are essential for evaluating long-term cardiac safety. Moreover, reliable prediction of pharmacological mechanisms of action remains a significant challenge. In this study, we employed field potential imaging utilizing an ultra-high-density complementary metal-oxide-semiconductor microelectrode array (MEA) comprising 236,880 electrodes distributed across a 5.9 × 5.5 mm active area. With 91.9% surface coverage by 11 μm electrodes spaced at 0.25 μm, the platform achieves near single-cell resolution across the entire cardiomyocyte monolayer. This system enabled the extraction of high-resolution electrophysiological endpoints, including the number and spatial variability of excitation origins, conduction velocity, and propagation area-thereby extending the analytical capabilities beyond those of conventional MEAs. Pharmacological testing revealed compound-specific alterations: Isoproterenol increased excitation origins, mexiletine reduced conduction velocity, and E-4031 diminished propagation area. Although these agents are well characterized, their effects were visualized with unprecedented spatiotemporal resolution, reflecting their underlying mechanisms of action. Multivariate analysis incorporating both conventional and novel endpoints enabled accurate classification of mechanisms under acute conditions. Furthermore, chronic cardiotoxicity induced by low-dose doxorubicin (0.03 μM) was sensitively detected within 24 h-earlier and at lower concentrations than previously reported-based on significant reductions in conduction velocity and propagation area. Collectively, these findings establish a high-resolution, mechanism-aware framework for in vitro cardiotoxicity profiling, offering improved predictive accuracy by capturing multi-ion channel interactions, spatial conduction abnormalities, and early signs of chronic dysfunction.

Toxicological SciencesVol. 208(2)
Tohoku Institute of Technology (JP), Impact Assessment (US), Eisai (Japan) (JP), National Institute of Advanced Industrial Science and Technology (JP)
Japan Agency for Medical Research and Development
Openalex Percentile: Top 23%
Integrated Circuits and Semiconductor Failure Analysis
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.