A holistic design of an energy-efficient data center with solar PV integration

The rapid growth of digital services has increased the demand for energy-intensive data centers, making sustainability and efficiency essential design priorities. This study presents the design and performance evaluation of a Tier III-compliant, 500 m² data center tailored to Ankara’s climatic conditions. Cooling loads were calculated using the CLTD method, resulting in a total internal heat gain of 470.63 kW, which guided the sizing of CRAH units and free-cooling-capable chillers. Detailed thermal analysis was combined with architectural planning, including cold aisle containment and raised flooring, to optimize airflow and energy use. The UPS system was sized at 462 kW to ensure continuous operation of critical loads, supported by redundant power generation. A rooftop PV system of 85.05 kWp was integrated, producing 192 MWh annually and covering 2.07% of the 9.28 GWh yearly demand, yielding cost savings of ~727,102 TRY. A ground-mounted PV system of 29.33 MWp was also proposed to meet the full annual energy demand, with an estimated saving potential of ~35.066 M TRY. The results demonstrate how integrating precise load estimation, energy-efficient cooling, and renewable generation can reduce both operational costs and environmental impact in mission-critical facilities, providing a replicable model for similar climates.

Authors

Institutions

Publication Details

Journal
International Journal of Energy Studies
Published
2025-09-25
DOI
https://doi.org/10.58559/ijes.1750386
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A holistic design of an energy-efficient data center with solar PV integration

Önder Kızılkan, Muhammed Burak Oyacı
International Journal of Energy Studies
Heat Transfer and Optimization
article

A holistic design of an energy-efficient data center with solar PV integration

Önder Kızılkan, Muhammed Burak Oyacı
article en

Abstract

The rapid growth of digital services has increased the demand for energy-intensive data centers, making sustainability and efficiency essential design priorities. This study presents the design and performance evaluation of a Tier III-compliant, 500 m² data center tailored to Ankara’s climatic conditions. Cooling loads were calculated using the CLTD method, resulting in a total internal heat gain of 470.63 kW, which guided the sizing of CRAH units and free-cooling-capable chillers. Detailed thermal analysis was combined with architectural planning, including cold aisle containment and raised flooring, to optimize airflow and energy use. The UPS system was sized at 462 kW to ensure continuous operation of critical loads, supported by redundant power generation. A rooftop PV system of 85.05 kWp was integrated, producing 192 MWh annually and covering 2.07% of the 9.28 GWh yearly demand, yielding cost savings of ~727,102 TRY. A ground-mounted PV system of 29.33 MWp was also proposed to meet the full annual energy demand, with an estimated saving potential of ~35.066 M TRY. The results demonstrate how integrating precise load estimation, energy-efficient cooling, and renewable generation can reduce both operational costs and environmental impact in mission-critical facilities, providing a replicable model for similar climates.

International Journal of Energy StudiesVol. 10(3)
Isparta University of Applied Sciences (TR)
Openalex Percentile: Top 72%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A holistic design of an energy-efficient data center with solar PV integration — Önder Kızılkan, Muhammed Burak Oyacı · International Journal of Energy Studies (2025) | TGRS Research Map | TGRS