A novel <i>C. elegans</i> respirometry assay using low-cost optical oxygen sensors

Measurement of the oxygen consumption rate, or respirometry, is a powerful and comprehensive method for assessing mitochondrial function both <i>in vitro</i> and <i>in vivo</i>. Respirometry at the whole-organism level has been repeatedly performed in the model organism <i>Caenorhabditis elegans</i>, typically using high-throughput microplate-based systems over traditional Clark-type respirometers. However, these systems are highly specialized, costly to purchase and operate, and inaccessible to many researchers. Here, we develop a respirometry assay using low-cost commercially available optical oxygen sensors (PreSens OxoPlates<sup>®</sup>) and fluorescence plate readers (the BMG FLUOstar), as an alternative to more costly standard respirometry systems. This assay uses standard BMG FLUOstar protocols and a set of custom scripts to perform repeated measurements of the <i>C. elegans</i> oxygen consumption rate, with the optional use of respiratory inhibitors or other interventions. We validate this assay by demonstrating the linearity of basal oxygen consumption rates in samples with variable numbers of animals, and by examining the impact of respiratory inhibitors with previously demonstrated efficacy in <i>C. elegans</i>: carbonyl cyanide 4-(trifluoromethoxy) phenylhydrazone (a mitochondrial uncoupler) and sodium azide (a Complex IV inhibitor). Using this assay, we demonstrate that the sequential use of FCCP and sodium azide leads to an increase in the sodium azide-treated (non-mitochondrial) oxygen consumption rate, indicating that the sequential use of respiratory inhibitors, as standard in intact cell respirometry, may produce erroneous estimates of non-mitochondrial respiration in <i>C. elegans</i> and thus should be avoided.

Authors

Institutions

Publication Details

Journal
Biology Methods and Protocols
Published
2025-01-01
DOI
https://doi.org/10.1093/biomethods/bpaf072
Primary Topic
Photoreceptor and optogenetics research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel C. elegans respirometry assay using low-cost optical oxygen sensors

Marina Ezcurra, W. J. Campbell, Nathan Dennis
Biology Methods and Protocols
Photoreceptor and optogenetics research
article

A novel C. elegans respirometry assay using low-cost optical oxygen sensors

Marina Ezcurra, W. J. Campbell, Nathan Dennis
article en

Abstract

Measurement of the oxygen consumption rate, or respirometry, is a powerful and comprehensive method for assessing mitochondrial function both <i>in vitro</i> and <i>in vivo</i>. Respirometry at the whole-organism level has been repeatedly performed in the model organism <i>Caenorhabditis elegans</i>, typically using high-throughput microplate-based systems over traditional Clark-type respirometers. However, these systems are highly specialized, costly to purchase and operate, and inaccessible to many researchers. Here, we develop a respirometry assay using low-cost commercially available optical oxygen sensors (PreSens OxoPlates<sup>®</sup>) and fluorescence plate readers (the BMG FLUOstar), as an alternative to more costly standard respirometry systems. This assay uses standard BMG FLUOstar protocols and a set of custom scripts to perform repeated measurements of the <i>C. elegans</i> oxygen consumption rate, with the optional use of respiratory inhibitors or other interventions. We validate this assay by demonstrating the linearity of basal oxygen consumption rates in samples with variable numbers of animals, and by examining the impact of respiratory inhibitors with previously demonstrated efficacy in <i>C. elegans</i>: carbonyl cyanide 4-(trifluoromethoxy) phenylhydrazone (a mitochondrial uncoupler) and sodium azide (a Complex IV inhibitor). Using this assay, we demonstrate that the sequential use of FCCP and sodium azide leads to an increase in the sodium azide-treated (non-mitochondrial) oxygen consumption rate, indicating that the sequential use of respiratory inhibitors, as standard in intact cell respirometry, may produce erroneous estimates of non-mitochondrial respiration in <i>C. elegans</i> and thus should be avoided.

Biology Methods and ProtocolsVol. 10(1)
University of Kent (GB)
National Institutes of Health, Directorate for Biological Sciences, Biotechnology and Biological Sciences Research Council
Openalex Percentile: Top 71%
Photoreceptor and optogenetics research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A novel <i>C. elegans</i> respirometry assay using low-cost optical oxygen sensors — Marina Ezcurra, W. J. Campbell, et al. · Biology Methods and Protocols (2025) | TGRS Research Map | TGRS