Investigation of the Impact of XLPE Cable Ageing on Impedance Mismatch Characteristics and Unbalanced Behaviour in Hybrid Operation Systems

ABSTRACT In the Hainan–Guangdong interconnection project, oil leakage in oil‐filled cables required replacing the faulty core with a single core from a three‐core cross‐linked polyethylene (XLPE) cable, leading to mixed operation of XLPE and oil‐filled cables. However, systematic quantitative analysis on the three‐phase unbalance caused by differences in material parameters between the two cable types is lacking. This study focuses on the mixed operation system, using a real‐time digital simulation platform to build power flow and current distribution models. Finite element thermal analysis and accelerated thermal ageing experiments were conducted to reveal the evolution of XLPE cable insulation dielectric parameters during ageing. Two evaluation indices, the impedance mismatch coefficient and the length mismatch coefficient, were proposed to quantify how material degradation worsens system unbalance. Results show that after 1440 h of ageing, the system's negative‐sequence and zero‐sequence unbalance increased by 24.4% and 28.7%, respectively. A critical impedance mismatch threshold is identified; once exceeded, unbalance escalates and the system's stability margin diminishes. This research provides theoretical support for recognising ageing‐induced sequence impedance mismatch and related unbalance effects in hybrid submarine cable systems and lays a foundation for optimising operational stability and designing compensation strategies.

Authors

Institutions

Publication Details

Journal
High Voltage
Published
2025-09-29
DOI
https://doi.org/10.1049/hve2.70106
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the Impact of XLPE Cable Ageing on Impedance Mismatch Characteristics and Unbalanced Behaviour in Hybrid Operation Systems

Liang Zou, Zhiyun Han, Shoushui Han, Zheng Liu et al.
High Voltage
High voltage insulation and dielectric phenomena
article

Investigation of the Impact of XLPE Cable Ageing on Impedance Mismatch Characteristics and Unbalanced Behaviour in Hybrid Operation Systems

Liang Zou, Zhiyun Han, Shoushui Han, Zheng Liu, Qingsong Liu
article en

Abstract

ABSTRACT In the Hainan–Guangdong interconnection project, oil leakage in oil‐filled cables required replacing the faulty core with a single core from a three‐core cross‐linked polyethylene (XLPE) cable, leading to mixed operation of XLPE and oil‐filled cables. However, systematic quantitative analysis on the three‐phase unbalance caused by differences in material parameters between the two cable types is lacking. This study focuses on the mixed operation system, using a real‐time digital simulation platform to build power flow and current distribution models. Finite element thermal analysis and accelerated thermal ageing experiments were conducted to reveal the evolution of XLPE cable insulation dielectric parameters during ageing. Two evaluation indices, the impedance mismatch coefficient and the length mismatch coefficient, were proposed to quantify how material degradation worsens system unbalance. Results show that after 1440 h of ageing, the system's negative‐sequence and zero‐sequence unbalance increased by 24.4% and 28.7%, respectively. A critical impedance mismatch threshold is identified; once exceeded, unbalance escalates and the system's stability margin diminishes. This research provides theoretical support for recognising ageing‐induced sequence impedance mismatch and related unbalance effects in hybrid submarine cable systems and lays a foundation for optimising operational stability and designing compensation strategies.

High Voltage
Electric Power Research Institute (US), Shandong University (CN), China Southern Power Grid (China) (CN)
Openalex Percentile: Top 79%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.