Estimation of the Optimum Etching Time and Etching Parameters for CR-39 Nuclear Tracks Detector by Applying Plasma and Chemical Etching Techniques

Background: CR-39 nuclear track detectors are widely used in various fields, including science, technology, astronomy, and environmental preservation, to detect and register heavy ions, neutrons, and alpha particles. Objective: This study aims to determine the optimal etching duration for CR-39 nuclear track detectors by comparing etching methods: The wet etching (using a water bath) and the dry etching technique (using dielectric barrier discharge (DBD) plasma). Methods: The traditional etching method involved immersing CR-39 detectors in a sodium hydroxide (NaOH) solution at 70 °C for varying durations. The dry etching method employed employs a non-thermal DBD plasma system to etch solid-state nuclear track detectors (SSNTDs) without the use of chemical solutions. Results: Photomicrographs revealed that tracks from chemical etching became clearly visible after 1 hour and developed at 5 hours. In contrast, the dry etching technique was significantly faster; tracks began to appear after just 1 minute of DBD plasma etching and were fully developed at 5 minutes. The optimum track density for DBD plasma was 20340±56 tracks/mm2 at 3 minutes, whereas the traditional water bath method achieved an optimum track density of 5238.0±5.7 tracks/mm2 at 2 hours. The shorter etching duration in the dry method likely facilitates the emergence of latent tracks without overlap. Conclusions: The bulk etch rate (VB) for CR-39 detectors using the dry DBD plasma etching technique was faster compared to the traditional chemical etching method. This demonstrates the efficacy of the dry etching process in significantly reducing etching time required for etching SSNDs.

Authors

Institutions

Publication Details

Journal
Al-Mustansiriyah Journal of Science
Published
2025-09-30
DOI
https://doi.org/10.23851/mjs.v36i3.1699
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
1.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimation of the Optimum Etching Time and Etching Parameters for CR-39 Nuclear Tracks Detector by Applying Plasma and Chemical Etching Techniques

Eldor Karimbaev, Jamoliddin Razzokov, Raghad S. Mohammed, Abdulkader Makki Dahham
1 citations
Al-Mustansiriyah Journal of Science
Radiation Detection and Scintillator Technologies
1.88
article

Estimation of the Optimum Etching Time and Etching Parameters for CR-39 Nuclear Tracks Detector by Applying Plasma and Chemical Etching Techniques

Eldor Karimbaev, Jamoliddin Razzokov, Raghad S. Mohammed, Abdulkader Makki Dahham
article en
1 citations

Abstract

Background: CR-39 nuclear track detectors are widely used in various fields, including science, technology, astronomy, and environmental preservation, to detect and register heavy ions, neutrons, and alpha particles. Objective: This study aims to determine the optimal etching duration for CR-39 nuclear track detectors by comparing etching methods: The wet etching (using a water bath) and the dry etching technique (using dielectric barrier discharge (DBD) plasma). Methods: The traditional etching method involved immersing CR-39 detectors in a sodium hydroxide (NaOH) solution at 70 °C for varying durations. The dry etching method employed employs a non-thermal DBD plasma system to etch solid-state nuclear track detectors (SSNTDs) without the use of chemical solutions. Results: Photomicrographs revealed that tracks from chemical etching became clearly visible after 1 hour and developed at 5 hours. In contrast, the dry etching technique was significantly faster; tracks began to appear after just 1 minute of DBD plasma etching and were fully developed at 5 minutes. The optimum track density for DBD plasma was 20340±56 tracks/mm2 at 3 minutes, whereas the traditional water bath method achieved an optimum track density of 5238.0±5.7 tracks/mm2 at 2 hours. The shorter etching duration in the dry method likely facilitates the emergence of latent tracks without overlap. Conclusions: The bulk etch rate (VB) for CR-39 detectors using the dry DBD plasma etching technique was faster compared to the traditional chemical etching method. This demonstrates the efficacy of the dry etching process in significantly reducing etching time required for etching SSNDs.

Al-Mustansiriyah Journal of ScienceVol. 36(3)
Mustansiriyah University (IQ), Tashkent Institute of Irrigation and Agricultural Mechanization Engineers (UZ)
Mustansiriyah University
Openalex Percentile: Top 12%
Radiation Detection and Scintillator Technologies
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.