Optimizing radiation safety: establishment of diagnostic reference levels for CT examinations in Northern Jordan

Abstract Introduction This study aims to establish a diagnostic reference level (DRL) for computed tomography (CT) examinations in northern Jordan, focusing on optimizing radiation doses in compliance with international standards. The goal is to minimize radiation exposure from routine CT scans of the brain, chest, and abdomen, safeguarding patient safety while enhancing diagnostic efficacy. Method Data of dose descriptor, including CT Dose Index (CTDIvol) and Dose Length Product (DLP), were collected from multiple hospitals across northern Jordan. The study involved a sample of 2200 patients, categorized into brain, chest, and abdomen CT groups. The 75th percentile of the median values of CTDIvol and DLP were calculated to determine DRL. Results DRL was set at 76 mGy for brain CT, 16 mGy for chest CT, and 24 mGy for abdomen CT. The DLP DRL was 1388.5 mGy·cm for the brain, 662 mGy·cm for the chest, and 1010 mGy·cm for the abdomen scans. The median CTDIvol values for brain, chest, and abdomen CT examinations were recorded as 73.6, 12.9, and 19.5 mGy, respectively. The corresponding DLP values for brain, chest, and abdomen CT were 1320.2 mGy·cm, 531 mGy cm, and 863 mGy cm. Conclusion The study establishes DRL for common CT examinations in northern Jordan for the first time. The DRL indicate that current radiation doses are exceeded national and international benchmarks, highlighting the need for optimization strategies. However, the increasing utilization of CT imaging necessitates ongoing monitoring and adjustments to mitigate long-term radiation risks.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Radiology and Nuclear Medicine
Published
2025-09-30
DOI
https://doi.org/10.1186/s43055-025-01600-3
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing radiation safety: establishment of diagnostic reference levels for CT examinations in Northern Jordan

Haytham Ahmad AL Ewaidat, Amro Alsaid, Laith Albadarneh, Azhar Abdul Rahman et al.
The Egyptian Journal of Radiology and Nuclear Medicine
Radiation Dose and Imaging
article

Optimizing radiation safety: establishment of diagnostic reference levels for CT examinations in Northern Jordan

Haytham Ahmad AL Ewaidat, Amro Alsaid, Laith Albadarneh, Azhar Abdul Rahman, Esraa Abu Lubad
article en

Abstract

Abstract Introduction This study aims to establish a diagnostic reference level (DRL) for computed tomography (CT) examinations in northern Jordan, focusing on optimizing radiation doses in compliance with international standards. The goal is to minimize radiation exposure from routine CT scans of the brain, chest, and abdomen, safeguarding patient safety while enhancing diagnostic efficacy. Method Data of dose descriptor, including CT Dose Index (CTDIvol) and Dose Length Product (DLP), were collected from multiple hospitals across northern Jordan. The study involved a sample of 2200 patients, categorized into brain, chest, and abdomen CT groups. The 75th percentile of the median values of CTDIvol and DLP were calculated to determine DRL. Results DRL was set at 76 mGy for brain CT, 16 mGy for chest CT, and 24 mGy for abdomen CT. The DLP DRL was 1388.5 mGy·cm for the brain, 662 mGy·cm for the chest, and 1010 mGy·cm for the abdomen scans. The median CTDIvol values for brain, chest, and abdomen CT examinations were recorded as 73.6, 12.9, and 19.5 mGy, respectively. The corresponding DLP values for brain, chest, and abdomen CT were 1320.2 mGy·cm, 531 mGy cm, and 863 mGy cm. Conclusion The study establishes DRL for common CT examinations in northern Jordan for the first time. The DRL indicate that current radiation doses are exceeded national and international benchmarks, highlighting the need for optimization strategies. However, the increasing utilization of CT imaging necessitates ongoing monitoring and adjustments to mitigate long-term radiation risks.

The Egyptian Journal of Radiology and Nuclear MedicineVol. 56(1)
Universiti Sains Malaysia (MY), Jordan University of Science and Technology (JO), Al al-Bayt University (JO)
Openalex Percentile: Top 60%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.