Lightning‐Induced Overvoltage on Overhead Distribution Line via Hybrid MTL‐PEEC Method

ABSTRACT Transient simulation are more economical and adaptable means of studying lightning overvoltage for overhead distribution line system compared to experiments. A hybrid multi‐transmission‐line (MTL)‐partial element equivalent circuit (PEEC) method proposed for lightning‐induced electromagnetic pulse (LEMP) simulation is verified using the rocket‐triggered experimental results under a more complex line configuration for the first time. This method can improve computational efficiency while ensuring calculation accuracy. The agreement between experimental and simulation results further validates the adaptability and accuracy of the proposed method, which is adopted to calculate the LEMP on the extended double‐circuit parallel unequal length line. The effects of various factors, such as the strike‐point location, the amplitude and waveform of the lightning current, the line shape and length on the amplitude of overvoltage and pole flashover along the line are discussed. For double‐circuit distribution lines, when lightning strikes the ground in front of centre of circuit I, the three‐phase voltage waveforms are similar, all of which are negative or bipolar oscillation waves. The closer the lightning strike point is to the line, the greater the amplitude of the lightning current, and the voltage waveform develops towards a bipolar waveform, but the main peak remains negative. As the amplitude of lightning current increases, the maximum lightning‐induced voltage amplitude along the line increases. The LEMP caused by the subsequent return‐stroke current is always greater than that caused by the first return‐stroke current. When the grounding resistance increases, the maximum voltage peak amplitude along the line remains unchanged.

Authors

Institutions

Publication Details

Journal
High Voltage
Published
2025-09-29
DOI
https://doi.org/10.1049/hve2.70095
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lightning‐Induced Overvoltage on Overhead Distribution Line via Hybrid MTL‐PEEC Method

Mi Zhou, Jianguo Wang, Jinxin Cao, Yuxuan Ding et al.
High Voltage
Lightning and Electromagnetic Phenomena
article

Lightning‐Induced Overvoltage on Overhead Distribution Line via Hybrid MTL‐PEEC Method

Mi Zhou, Jianguo Wang, Jinxin Cao, Yuxuan Ding, Yating Zhao, Runyu Fu, Li Cai, Yaping Du
article en

Abstract

ABSTRACT Transient simulation are more economical and adaptable means of studying lightning overvoltage for overhead distribution line system compared to experiments. A hybrid multi‐transmission‐line (MTL)‐partial element equivalent circuit (PEEC) method proposed for lightning‐induced electromagnetic pulse (LEMP) simulation is verified using the rocket‐triggered experimental results under a more complex line configuration for the first time. This method can improve computational efficiency while ensuring calculation accuracy. The agreement between experimental and simulation results further validates the adaptability and accuracy of the proposed method, which is adopted to calculate the LEMP on the extended double‐circuit parallel unequal length line. The effects of various factors, such as the strike‐point location, the amplitude and waveform of the lightning current, the line shape and length on the amplitude of overvoltage and pole flashover along the line are discussed. For double‐circuit distribution lines, when lightning strikes the ground in front of centre of circuit I, the three‐phase voltage waveforms are similar, all of which are negative or bipolar oscillation waves. The closer the lightning strike point is to the line, the greater the amplitude of the lightning current, and the voltage waveform develops towards a bipolar waveform, but the main peak remains negative. As the amplitude of lightning current increases, the maximum lightning‐induced voltage amplitude along the line increases. The LEMP caused by the subsequent return‐stroke current is always greater than that caused by the first return‐stroke current. When the grounding resistance increases, the maximum voltage peak amplitude along the line remains unchanged.

High VoltageVol. 10(6)
Hong Kong Polytechnic University (HK), Wuhan University of Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 81%
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.