Penggunaan Pitch Rendah pada Pemeriksaan CT Scan Kepala pada Kasus Trauma di RSUD Banyumas

RSUD (Regional General Hospital) Banyumas is a healthcare institution offering radiology services, such as head CT scans for trauma cases. The application of CT scan pitch parameters is essential for generating high-quality images while reducing the radiation exposure to the patient. This study employed a descriptive qualitative methodology utilizing a case study approach. The author presents an analysis of low pitch utilization in head CT scans for trauma cases at RSUD Banyumas. The research was carried out between May and June 2025. The participants included three radiographers and one radiologist. The methods employed for data collection comprised observation, interviews, and documentation. The study results demonstrate that the CT scan procedure for head trauma at RSUD Banyumas was executed with the patient in a supine head-first position and a pitch parameter set at 0.55. Employing a lower pitch enhances image detail and noise, although with the potential for increased radiation exposure. This study concludes that appropriate pitch utilization in head trauma CT scans at RSUD Banyumas significantly affects image quality.

Authors

Institutions

Publication Details

Journal
Jurnal Kesehatan Amanah
Published
2025-09-30
DOI
https://doi.org/10.57214/jka.v9i2.964
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Penggunaan Pitch Rendah pada Pemeriksaan CT Scan Kepala pada Kasus Trauma di RSUD Banyumas

Aliya Ambar Sari, Widya Mufida, Muhammad Za’im
Jurnal Kesehatan Amanah
Medical Imaging and Analysis
article

Penggunaan Pitch Rendah pada Pemeriksaan CT Scan Kepala pada Kasus Trauma di RSUD Banyumas

Aliya Ambar Sari, Widya Mufida, Muhammad Za’im
article en

Abstract

RSUD (Regional General Hospital) Banyumas is a healthcare institution offering radiology services, such as head CT scans for trauma cases. The application of CT scan pitch parameters is essential for generating high-quality images while reducing the radiation exposure to the patient. This study employed a descriptive qualitative methodology utilizing a case study approach. The author presents an analysis of low pitch utilization in head CT scans for trauma cases at RSUD Banyumas. The research was carried out between May and June 2025. The participants included three radiographers and one radiologist. The methods employed for data collection comprised observation, interviews, and documentation. The study results demonstrate that the CT scan procedure for head trauma at RSUD Banyumas was executed with the patient in a supine head-first position and a pitch parameter set at 0.55. Employing a lower pitch enhances image detail and noise, although with the potential for increased radiation exposure. This study concludes that appropriate pitch utilization in head trauma CT scans at RSUD Banyumas significantly affects image quality.

Jurnal Kesehatan AmanahVol. 9(2)
Universitas 'Aisyiyah Yogyakarta
Openalex Percentile: Top 74%
Medical Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.