Demonstrating voxel-by-voxel (V × V) single-point calibration in liver tissue by IR-MALDESI quantitative MSI

Quantitative mass spectrometry imaging (qMSI) provides information regarding the colocalization, relative abundance, and concentration of a target analyte in a tissue without homogenization. Ionization sources, including IR-MALDESI, commonly utilize an on-tissue spatial calibration curve approach; however, this approach has several limitations including tedious sample preparation, and this approach does not account for local matrix effects. To compensate for these two limitations, we developed voxel-by-voxel (V × V) quantification to provide an internal standard calibration point for every voxel which requires a simple sample preparation and accounts for local matrix effects. In this work, we evaluate the performance of V × V quantification against the spatial calibration curve to assess the quantitative capacity of this newly developed method. Quantification of glutathione (GSH) on a per-voxel basis involves homogenously spraying a known amount of stable isotope-labeled glutathione (SIL-GSH) on a microscope slide. Next, we mount liver sections on top of the coated slides and image them using IR-MALDESI MSI. Statistical analysis demonstrated high precision for V × V quantification over a wide concentration range; however, the method's accuracy is currently limited due to the sprayer's configuration. Results support the feasibility of V × V quantification as evidenced by concentration heatmaps. Additionally, V × V quantification allows for parallel reaction monitoring (PRM) imaging which provides high specificity. Combined with relativity, straightforward sample preparation, and promising initial statistics, the V × V method offers significant advantages over spatial calibration curves.

Authors

Institutions

Publication Details

Journal
Analytical and Bioanalytical Chemistry
Published
2025-09-29
DOI
https://doi.org/10.1007/s00216-025-06138-x
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Demonstrating voxel-by-voxel (V × V) single-point calibration in liver tissue by IR-MALDESI quantitative MSI

David C. Muddiman, Russell R. Kibbe, Emily R. Bruce, Logan J. Opperman
Analytical and Bioanalytical Chemistry
Mass Spectrometry Techniques and Applications
article

Demonstrating voxel-by-voxel (V × V) single-point calibration in liver tissue by IR-MALDESI quantitative MSI

David C. Muddiman, Russell R. Kibbe, Emily R. Bruce, Logan J. Opperman
article en

Abstract

Quantitative mass spectrometry imaging (qMSI) provides information regarding the colocalization, relative abundance, and concentration of a target analyte in a tissue without homogenization. Ionization sources, including IR-MALDESI, commonly utilize an on-tissue spatial calibration curve approach; however, this approach has several limitations including tedious sample preparation, and this approach does not account for local matrix effects. To compensate for these two limitations, we developed voxel-by-voxel (V × V) quantification to provide an internal standard calibration point for every voxel which requires a simple sample preparation and accounts for local matrix effects. In this work, we evaluate the performance of V × V quantification against the spatial calibration curve to assess the quantitative capacity of this newly developed method. Quantification of glutathione (GSH) on a per-voxel basis involves homogenously spraying a known amount of stable isotope-labeled glutathione (SIL-GSH) on a microscope slide. Next, we mount liver sections on top of the coated slides and image them using IR-MALDESI MSI. Statistical analysis demonstrated high precision for V × V quantification over a wide concentration range; however, the method's accuracy is currently limited due to the sprayer's configuration. Results support the feasibility of V × V quantification as evidenced by concentration heatmaps. Additionally, V × V quantification allows for parallel reaction monitoring (PRM) imaging which provides high specificity. Combined with relativity, straightforward sample preparation, and promising initial statistics, the V × V method offers significant advantages over spatial calibration curves.

Analytical and Bioanalytical ChemistryVol. 417(28)
North Carolina State University (US)
U.S. Department of Education, North Carolina State University, National Institutes of Health
Openalex Percentile: Top 75%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.