Polyoxometalate‐Based MOF as a Highly Sensitive and Stable X‐ray Detector for Imaging

Polyoxometalate-based metal-organic frameworks (POMOFs) show potential application prospects in the field of X-ray detection in recent years. However, it is still unclear how to effectively separate X-ray-induced charge carriers through the effective connection between polyoxometalates (POMs) and metal-organic frameworks (MOFs) due to their current infancy research status. Here, we designed and fabricated a novel POMOF BW<sub>12</sub>-Cu<sup>II</sup>-MOF-based X-ray detector for stable and sensitive X-ray detection and imaging. The Cu─O coordination bonds between [BW<sub>12</sub>O<sub>40</sub>]<sup>5-</sup> and [Cu(2,2'-bipy)<sub>2</sub>]<sup>2+</sup> in the structure of BW<sub>12</sub>-Cu<sup>II</sup>-MOF are not only conducive to charge transfer between anion and cation, resulting in a high hole carrier mobility (μ<sub>h</sub>) of 4.80 cm<sup>2</sup> V<sup>-1</sup> s<sup>-1</sup>, but also effectively reduce ion migration and dark current simultaneously, which causes a small dark current drift as low as 1.2 × 10<sup>-18</sup> A cm<sup>-1</sup> V<sup>-1</sup> s<sup>-1</sup>. Finally, the fabricated BW<sub>12</sub>-Cu<sup>II</sup>-MOF wafer device shows excellent X-ray detection performances, yielding a high sensitivity of 9832 µC Gy<sub>air</sub> <sup>-1</sup> cm<sup>-2</sup> with the lowest detectable dose rate of 120 nGy<sub>air</sub> s<sup>-1</sup> at an electric field of 200 V mm<sup>-1</sup> under 80 kV X-ray irradiation. Furthermore, the constructed POMOF BW<sub>12</sub>-Cu<sup>II</sup>-MOF as a potential candidate for X-ray detection also exhibits good X-ray imaging capability and long-term operational stability without any encapsulation exposed to the air for 6 months.

Authors

Institutions

Publication Details

Journal
Angewandte Chemie International Edition
Published
2025-09-28
DOI
https://doi.org/10.1002/anie.202518832
Citations
2
Primary Topic
Perovskite Materials and Applications
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Polyoxometalate‐Based MOF as a Highly Sensitive and Stable X‐ray Detector for Imaging

Yanli Yang, Cheng Wang, Bairu Li, Keke Guo
2 citations
Angewandte Chemie International Edition
Perovskite Materials and Applications
1.46
article

Polyoxometalate‐Based MOF as a Highly Sensitive and Stable X‐ray Detector for Imaging

Yanli Yang, Cheng Wang, Bairu Li, Keke Guo
article en
2 citations

Abstract

Polyoxometalate-based metal-organic frameworks (POMOFs) show potential application prospects in the field of X-ray detection in recent years. However, it is still unclear how to effectively separate X-ray-induced charge carriers through the effective connection between polyoxometalates (POMs) and metal-organic frameworks (MOFs) due to their current infancy research status. Here, we designed and fabricated a novel POMOF BW<sub>12</sub>-Cu<sup>II</sup>-MOF-based X-ray detector for stable and sensitive X-ray detection and imaging. The Cu─O coordination bonds between [BW<sub>12</sub>O<sub>40</sub>]<sup>5-</sup> and [Cu(2,2'-bipy)<sub>2</sub>]<sup>2+</sup> in the structure of BW<sub>12</sub>-Cu<sup>II</sup>-MOF are not only conducive to charge transfer between anion and cation, resulting in a high hole carrier mobility (μ<sub>h</sub>) of 4.80 cm<sup>2</sup> V<sup>-1</sup> s<sup>-1</sup>, but also effectively reduce ion migration and dark current simultaneously, which causes a small dark current drift as low as 1.2 × 10<sup>-18</sup> A cm<sup>-1</sup> V<sup>-1</sup> s<sup>-1</sup>. Finally, the fabricated BW<sub>12</sub>-Cu<sup>II</sup>-MOF wafer device shows excellent X-ray detection performances, yielding a high sensitivity of 9832 µC Gy<sub>air</sub> <sup>-1</sup> cm<sup>-2</sup> with the lowest detectable dose rate of 120 nGy<sub>air</sub> s<sup>-1</sup> at an electric field of 200 V mm<sup>-1</sup> under 80 kV X-ray irradiation. Furthermore, the constructed POMOF BW<sub>12</sub>-Cu<sup>II</sup>-MOF as a potential candidate for X-ray detection also exhibits good X-ray imaging capability and long-term operational stability without any encapsulation exposed to the air for 6 months.

Angewandte Chemie International EditionVol. 64(48)
Northeast Normal University (CN), Chaohu University (CN), Northwest Normal University (CN)
Openalex Percentile: Top 15%
Perovskite Materials and Applications
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Polyoxometalate‐Based MOF as a Highly Sensitive and Stable X‐ray Detector for Imaging — Yanli Yang, Cheng Wang, et al. · Angewandte Chemie International Edition (2025) | TGRS Research Map | TGRS