Incorporation of optical profilometry volume correction in quantitative elemental bioimaging workflows

Quantitative elemental bioimaging workflows are well established and typically rely on matrix-matched standards for comparable and repeatable calibration. However, variations in tissue thickness, microtome cutting artefacts, and cell density are usually assumed to have negligible impact on method uncertainties. Common mitigation strategies include endogenous signal normalization with <sup>12</sup>C or <sup>31</sup>P, complete ablation of thin sections, or analysis of thicker specimens under stable laser fluences. While effective for homogeneous specimens, these approaches may fail in heterogeneous tissues with disparate anatomical structures, variable cell populations, or inconsistencies in sectioning, leading to uncontrolled anomalies and potentially misleading interpretation of elemental distributions. To overcome these limitations, here we incorporate optical profilometry into quantitative bioimaging workflows to directly measure tissue surface topographies and correct for thickness variations. Topographic maps were acquired for gelatin standards and representative tissues, including murine kidney, multi-organ arrays, human meningioma, and emphysematous lung, revealing substantial deviations from nominal thicknesses and heterogeneous surface roughness. These data were registered against LA-ICP-MS elemental images and applied for volume normalization. Volume correction significantly altered elemental quantification. In kidney, Cu, Fe, and Zn increased 4-5 fold, whereas in meningioma, Cu and Fe increased 8-10 fold, with Zn similarly elevated. Correlations of endogenous signals with thickness were tissue-dependent: in the kidney, <sup>12</sup>C strongly correlated (R = 0.66) and <sup>31</sup>P moderately (R = 0.44), while in the meningioma, both were weak (<sup>12</sup>C R = 0.21; <sup>31</sup>P R = 0.09), though <sup>31</sup>P moderately tracked cell density (R = 0.51). These results demonstrate that profilometry-based volume correction improves accuracy, reproducibility, and interpretability of elemental bioimaging, particularly in heterogeneous tissues.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2025-09-29
DOI
https://doi.org/10.1016/j.talanta.2025.128923
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Incorporation of optical profilometry volume correction in quantitative elemental bioimaging workflows

Philip Doble, Janice I. McCauley, Mika T. Westerhausen, Dayanne Mozaner Bordin et al.
Talanta
Photoacoustic and Ultrasonic Imaging
article

Incorporation of optical profilometry volume correction in quantitative elemental bioimaging workflows

Philip Doble, Janice I. McCauley, Mika T. Westerhausen, Dayanne Mozaner Bordin, Thomas R. Cox, Astrid Jeibmann, Jessica L. Chitty, Thomas E. Lockwood
article en

Abstract

Quantitative elemental bioimaging workflows are well established and typically rely on matrix-matched standards for comparable and repeatable calibration. However, variations in tissue thickness, microtome cutting artefacts, and cell density are usually assumed to have negligible impact on method uncertainties. Common mitigation strategies include endogenous signal normalization with <sup>12</sup>C or <sup>31</sup>P, complete ablation of thin sections, or analysis of thicker specimens under stable laser fluences. While effective for homogeneous specimens, these approaches may fail in heterogeneous tissues with disparate anatomical structures, variable cell populations, or inconsistencies in sectioning, leading to uncontrolled anomalies and potentially misleading interpretation of elemental distributions. To overcome these limitations, here we incorporate optical profilometry into quantitative bioimaging workflows to directly measure tissue surface topographies and correct for thickness variations. Topographic maps were acquired for gelatin standards and representative tissues, including murine kidney, multi-organ arrays, human meningioma, and emphysematous lung, revealing substantial deviations from nominal thicknesses and heterogeneous surface roughness. These data were registered against LA-ICP-MS elemental images and applied for volume normalization. Volume correction significantly altered elemental quantification. In kidney, Cu, Fe, and Zn increased 4-5 fold, whereas in meningioma, Cu and Fe increased 8-10 fold, with Zn similarly elevated. Correlations of endogenous signals with thickness were tissue-dependent: in the kidney, <sup>12</sup>C strongly correlated (R = 0.66) and <sup>31</sup>P moderately (R = 0.44), while in the meningioma, both were weak (<sup>12</sup>C R = 0.21; <sup>31</sup>P R = 0.09), though <sup>31</sup>P moderately tracked cell density (R = 0.51). These results demonstrate that profilometry-based volume correction improves accuracy, reproducibility, and interpretability of elemental bioimaging, particularly in heterogeneous tissues.

TalantaVol. 298(Pt B)
University of Technology Sydney (AU), Garvan Institute of Medical Research (AU), University Hospital Münster (DE)
Openalex Percentile: Top 74%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.