Evaluation of Measurement Uncertainty in Waste Cadmium Analysis

This study used inductively coupled plasma optical emission spectrometry to evaluate the uncertainty associated with measuring the cadmium content in waste sample. In this study, the uncertainty factors were divided into acid digestion, standard solutions for calibration curve, calibration curve, and repeated measurement. The cadmium content was determined to be 109.12 ± 3.60 mg/kg. In addition, it had a significant impact on the uncertainty in the calibration curve and the standard solutions for constructing the calibration curve. The uncertainty in the calibration curve can be reduced by increasing the concentration of the standard solution, as proposed in previous studies. In addition, to reduce the uncertainty that arises from preparing standard solutions, an alternative would be to pipette the liquid as the weight corresponding to the target volume instead of the volume itself.

Authors

Publication Details

Journal
Journal of Environmental Analysis Health and Toxicology
Published
2025-09-29
DOI
https://doi.org/10.36278/jeaht.28.3.152
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Measurement Uncertainty in Waste Cadmium Analysis

Dae Han Choi
Journal of Environmental Analysis Health and Toxicology
Non-Destructive Testing Techniques
article

Evaluation of Measurement Uncertainty in Waste Cadmium Analysis

Dae Han Choi
article en

Abstract

This study used inductively coupled plasma optical emission spectrometry to evaluate the uncertainty associated with measuring the cadmium content in waste sample. In this study, the uncertainty factors were divided into acid digestion, standard solutions for calibration curve, calibration curve, and repeated measurement. The cadmium content was determined to be 109.12 ± 3.60 mg/kg. In addition, it had a significant impact on the uncertainty in the calibration curve and the standard solutions for constructing the calibration curve. The uncertainty in the calibration curve can be reduced by increasing the concentration of the standard solution, as proposed in previous studies. In addition, to reduce the uncertainty that arises from preparing standard solutions, an alternative would be to pipette the liquid as the weight corresponding to the target volume instead of the volume itself.

Journal of Environmental Analysis Health and ToxicologyVol. 28(3)
Openalex Percentile: Top 72%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.