Voltammetric Determination of Hydroxychloroquine Used in the Treatment of COVID‐19 at MWCNT Modified Pencil Graphite Electrode

COVID-19, the most significant pandemic of the 21st century, has prompted the use of various drugs to slow down the viral process in patients infected with it. One of these drugs is hydroxychloroquine, and due to its importance and frequent use in the treatment of COVID-19, its rapid, accurate and inexpensive determination in biological or pharmaceutical samples is very important. In this study, the electrochemical behavior of hydroxychloroquine was investigated, and voltammetric determination of hydroxychloroquine was performed with a pencil graphite electrode modified with multi-walled carbon nanotubes. Scanning electron microscopy images were used to examine the surfaces of both the regular pencil graphite electrode and the modified one with multi-walled carbon nanotube. Cyclic voltammetric measurements showed that hydroxychloroquine was irreversibly oxidized at approximately +700 and +900 mV in Britton Robinson buffer solution at pH 10.0. Considering these oxidation peaks, differential pulse voltammetric determination of hydroxychloroquine was carried out under optimized conditions. A linear response was obtained from the multi-walled carbon nanotube-modified pencil graphite electrode in the range of 0.1 to 200 µmolL-1 for peaks at both +700 mV and +900 mV with detection limits of 0.04 and 0.05 µmolL-1, respectively. The method was tested on the real tablet and water samples; nearly 100 % recovery was achieved for hydroxychloroquine spiked into the water sample, while the amount of the labeled compound in the pharmaceutical tablet was accurately determined. This result confirmed that the multi-walled carbon nanotube-modified pencil graphite electrode is very effective for selectively and accurately determining hydroxychloroquine in real samples.

Authors

Institutions

Publication Details

Journal
Celal Bayar Üniversitesi Fen Bilimleri Dergisi
Published
2025-09-26
DOI
https://doi.org/10.18466/cbayarfbe.1705373
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Voltammetric Determination of Hydroxychloroquine Used in the Treatment of COVID‐19 at MWCNT Modified Pencil Graphite Electrode

Selen Ayaz, Didem Giray Dilgin, İrem Demir, Sultan Hasankahyaoğlu et al.
Celal Bayar Üniversitesi Fen Bilimleri Dergisi
Antibiotics Pharmacokinetics and Efficacy
article

Voltammetric Determination of Hydroxychloroquine Used in the Treatment of COVID‐19 at MWCNT Modified Pencil Graphite Electrode

Selen Ayaz, Didem Giray Dilgin, İrem Demir, Sultan Hasankahyaoğlu, Şevval Sazlık
article en

Abstract

COVID-19, the most significant pandemic of the 21st century, has prompted the use of various drugs to slow down the viral process in patients infected with it. One of these drugs is hydroxychloroquine, and due to its importance and frequent use in the treatment of COVID-19, its rapid, accurate and inexpensive determination in biological or pharmaceutical samples is very important. In this study, the electrochemical behavior of hydroxychloroquine was investigated, and voltammetric determination of hydroxychloroquine was performed with a pencil graphite electrode modified with multi-walled carbon nanotubes. Scanning electron microscopy images were used to examine the surfaces of both the regular pencil graphite electrode and the modified one with multi-walled carbon nanotube. Cyclic voltammetric measurements showed that hydroxychloroquine was irreversibly oxidized at approximately +700 and +900 mV in Britton Robinson buffer solution at pH 10.0. Considering these oxidation peaks, differential pulse voltammetric determination of hydroxychloroquine was carried out under optimized conditions. A linear response was obtained from the multi-walled carbon nanotube-modified pencil graphite electrode in the range of 0.1 to 200 µmolL-1 for peaks at both +700 mV and +900 mV with detection limits of 0.04 and 0.05 µmolL-1, respectively. The method was tested on the real tablet and water samples; nearly 100 % recovery was achieved for hydroxychloroquine spiked into the water sample, while the amount of the labeled compound in the pharmaceutical tablet was accurately determined. This result confirmed that the multi-walled carbon nanotube-modified pencil graphite electrode is very effective for selectively and accurately determining hydroxychloroquine in real samples.

Celal Bayar Üniversitesi Fen Bilimleri DergisiVol. 21(3)
Çanakkale Onsekiz Mart Üniversitesi (TR)
Openalex Percentile: Top 70%
Antibiotics Pharmacokinetics and Efficacy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Voltammetric Determination of Hydroxychloroquine Used in the Treatment of COVID‐19 at MWCNT Modified Pencil Graphite Electrode — Selen Ayaz, Didem Giray Dilgin, et al. · Celal Bayar Üniversitesi Fen Bilimleri Dergisi (2025) | TGRS Research Map | TGRS