Diagnostic Accuracy of DaTQUANT® Versus BasGanV2™ for 123I-Ioflupane Brain SPECT: A Machine Learning-Based Differentiation of Parkinson’s Disease and Essential Tremor

<b>Background</b>: Differentiating Parkinson's disease (PD) from essential tremor (ET) is often challenging, especially in early or atypical cases. Dopamine transporter (DAT) single-photon emission computed tomography (SPECT) with <sup>123</sup>I-Ioflupane supports diagnosis, and semi-quantitative tools such as DaTQUANT<sup>®</sup> and BasGanV2™ provide objective measures. This study compared their diagnostic performance when integrated with supervised machine learning. <b>Methods</b>: We retrospectively analysed <sup>123</sup>I-Ioflupane SPECT scans from 169 patients (133 PD, 36 ET). Semi-quantitative analysis was performed using DaTQUANT<sup>®</sup> v2.0 and BasGanV2™ v.2. Classification tree (ClT), k-nearest neighbour (k-NN), and support vector machine (SVM) models were trained and validated with stratified shuffle split (250 iterations). Diagnostic accuracy was compared between the two software packages. <b>Results</b>: All classifiers reliably distinguished PD from ET. DaTQUANT<sup>®</sup> consistently achieved higher accuracy than BasGanV2™: 93.8%, 93.2%, and 94.5% for ClT, k-NN, and SVM, respectively, versus 90.9%, 91.7%, and 91.9% for BasGanV2™ (<i>p</i> < 0.001). Sensitivity and specificity were also consistently higher for DaTQUANT<sup>®</sup> than BasGanV2. Class imbalance (PD > ET) was addressed using Synthetic Minority Over-sampling Technique (SMOTE). <b>Conclusions</b>: Machine learning analysis of <sup>123</sup>I-Ioflupane SPECT enhances differentiation between PD and ET. DaTQUANT<sup>®</sup> outperformed BasGanV2™, suggesting greater suitability for AI-driven decision support. These findings support the integration of semi-quantitative and AI-based approaches into clinical workflows and highlight the need for harmonised methodologies in movement disorder imaging.

Authors

Institutions

Publication Details

Journal
Biomedicines
Published
2025-09-27
DOI
https://doi.org/10.3390/biomedicines13102367
Primary Topic
Neurological disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Accuracy of DaTQUANT® Versus BasGanV2™ for 123I-Ioflupane Brain SPECT: A Machine Learning-Based Differentiation of Parkinson’s Disease and Essential Tremor

Viviana Frantellizzi, Francesco Bianconi, Susanna Nuvoli, Angela Spanu et al.
Biomedicines
Neurological disorders and treatments
article

Diagnostic Accuracy of DaTQUANT® Versus BasGanV2™ for 123I-Ioflupane Brain SPECT: A Machine Learning-Based Differentiation of Parkinson’s Disease and Essential Tremor

Viviana Frantellizzi, Francesco Bianconi, Susanna Nuvoli, Angela Spanu, Giuseppe De Vincentis, Luca Filippi, Andrea Marongiu, Mario Luca Fravolini, Barbara Palumbo, Roberta Danieli
article en

Abstract

<b>Background</b>: Differentiating Parkinson's disease (PD) from essential tremor (ET) is often challenging, especially in early or atypical cases. Dopamine transporter (DAT) single-photon emission computed tomography (SPECT) with <sup>123</sup>I-Ioflupane supports diagnosis, and semi-quantitative tools such as DaTQUANT<sup>®</sup> and BasGanV2™ provide objective measures. This study compared their diagnostic performance when integrated with supervised machine learning. <b>Methods</b>: We retrospectively analysed <sup>123</sup>I-Ioflupane SPECT scans from 169 patients (133 PD, 36 ET). Semi-quantitative analysis was performed using DaTQUANT<sup>®</sup> v2.0 and BasGanV2™ v.2. Classification tree (ClT), k-nearest neighbour (k-NN), and support vector machine (SVM) models were trained and validated with stratified shuffle split (250 iterations). Diagnostic accuracy was compared between the two software packages. <b>Results</b>: All classifiers reliably distinguished PD from ET. DaTQUANT<sup>®</sup> consistently achieved higher accuracy than BasGanV2™: 93.8%, 93.2%, and 94.5% for ClT, k-NN, and SVM, respectively, versus 90.9%, 91.7%, and 91.9% for BasGanV2™ (<i>p</i> < 0.001). Sensitivity and specificity were also consistently higher for DaTQUANT<sup>®</sup> than BasGanV2. Class imbalance (PD > ET) was addressed using Synthetic Minority Over-sampling Technique (SMOTE). <b>Conclusions</b>: Machine learning analysis of <sup>123</sup>I-Ioflupane SPECT enhances differentiation between PD and ET. DaTQUANT<sup>®</sup> outperformed BasGanV2™, suggesting greater suitability for AI-driven decision support. These findings support the integration of semi-quantitative and AI-based approaches into clinical workflows and highlight the need for harmonised methodologies in movement disorder imaging.

BiomedicinesVol. 13(10)
University of Rome Tor Vergata (IT), Vita-Salute San Raffaele University (IT), University of Sassari (IT), University of Perugia (IT), Azienda Ospedaliera di Perugia (IT), IRCCS Ospedale San Raffaele (IT), Sapienza University of Rome (IT)
Openalex Percentile: Top 62%
Neurological disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.