Comparison of Localization Methods in Cushing Disease—Could [11C]C-Methionine PET/CT Replace MRI or BIPSS?

<b>Introduction</b>: Cushing syndrome (CS) is a medical condition resulting from prolonged hypercortisolemia. The most common reason for endogenous CS is ACTH overproduction by pituitary adenoma, and then it is called Cushing disease (CD). The gold standard of CD diagnostic remains bilateral inferior petrosal sinus sampling (BIPSS); nevertheless, non-invasive diagnostic methods are being sought to provide a higher safety profile. The aim of this study was to evaluate whether [<sup>11</sup>C]C-MET PET/CT can serve as a non-invasive alternative to BIPSS and MRI in CD diagnosis. <b>Methods</b>: This prospective study included 21 patients with CD who underwent BIPSS, MRI of the pituitary, and [<sup>11</sup>C]C-MET PET/CT. <b>Results</b>: Sensitivity of BIPSS, MRI and [<sup>11</sup>C]C-MET PET/CT was 100%, 59% and 24%, respectively, while specificity was 100%, 75%, and 13%. Next, we retrospectively compared PET/CT results for patients with corticotrope pituitary adenomas (<i>n</i> = 18) with those for individuals with no pituitary pathology (<i>n</i> = 18), and the results showed significantly higher SUV<sub>max</sub> in the study group (3.74 ± 0.90 vs. 1.87 ± 1.17; <i>p</i> < 0.001). In ROC curve analysis, the area under the curve (AUC) was 0.889 (<i>p</i> <0.001; 95% CI 0.784-0.994). For SUV<sub>max</sub> 2.60, the calculated sensitivity and specificity were 89% and 78% respectively, and for SUV<sub>max</sub> 3.56, sensitivity and specificity were 67% and 89%, respectively. <b>Conclusions</b>: [<sup>11</sup>C]C-MET PET/CT seems not to be a reliable diagnostic option in the diagnosis of pituitary corticotropic adenomas. BIPSS proved still to be the best diagnostic option for CD. Nevertheless, a higher than normal pituitary accumulation of the radiotracer may suggest the presence of increased amino acid metabolism, thus, the presence of adenoma.

Authors

Institutions

Publication Details

Journal
Cancers
Published
2025-09-27
DOI
https://doi.org/10.3390/cancers17193147
Primary Topic
Pituitary Gland Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Localization Methods in Cushing Disease—Could [11C]C-Methionine PET/CT Replace MRI or BIPSS?

Piotr Zięcina, Marek Saracyn, Jerzy Narloch, Grzegorz Zieliński et al.
Cancers
Pituitary Gland Disorders and Treatments
article

Comparison of Localization Methods in Cushing Disease—Could [11C]C-Methionine PET/CT Replace MRI or BIPSS?

Piotr Zięcina, Marek Saracyn, Jerzy Narloch, Grzegorz Zieliński, Adam Daniel Durma, Maciej Kołodziej, Grzegorz Kamiński
article en

Abstract

<b>Introduction</b>: Cushing syndrome (CS) is a medical condition resulting from prolonged hypercortisolemia. The most common reason for endogenous CS is ACTH overproduction by pituitary adenoma, and then it is called Cushing disease (CD). The gold standard of CD diagnostic remains bilateral inferior petrosal sinus sampling (BIPSS); nevertheless, non-invasive diagnostic methods are being sought to provide a higher safety profile. The aim of this study was to evaluate whether [<sup>11</sup>C]C-MET PET/CT can serve as a non-invasive alternative to BIPSS and MRI in CD diagnosis. <b>Methods</b>: This prospective study included 21 patients with CD who underwent BIPSS, MRI of the pituitary, and [<sup>11</sup>C]C-MET PET/CT. <b>Results</b>: Sensitivity of BIPSS, MRI and [<sup>11</sup>C]C-MET PET/CT was 100%, 59% and 24%, respectively, while specificity was 100%, 75%, and 13%. Next, we retrospectively compared PET/CT results for patients with corticotrope pituitary adenomas (<i>n</i> = 18) with those for individuals with no pituitary pathology (<i>n</i> = 18), and the results showed significantly higher SUV<sub>max</sub> in the study group (3.74 ± 0.90 vs. 1.87 ± 1.17; <i>p</i> < 0.001). In ROC curve analysis, the area under the curve (AUC) was 0.889 (<i>p</i> <0.001; 95% CI 0.784-0.994). For SUV<sub>max</sub> 2.60, the calculated sensitivity and specificity were 89% and 78% respectively, and for SUV<sub>max</sub> 3.56, sensitivity and specificity were 67% and 89%, respectively. <b>Conclusions</b>: [<sup>11</sup>C]C-MET PET/CT seems not to be a reliable diagnostic option in the diagnosis of pituitary corticotropic adenomas. BIPSS proved still to be the best diagnostic option for CD. Nevertheless, a higher than normal pituitary accumulation of the radiotracer may suggest the presence of increased amino acid metabolism, thus, the presence of adenoma.

CancersVol. 17(19)
National Academy of Medicine (US), Medical University of Warsaw (PL), Wojskowy Instytut Medycyny Lotniczej (PL), University of Warsaw (PL)
Openalex Percentile: Top 64%
Pituitary Gland Disorders and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.