Study on the Fire Temperature Pattern of Tunnels with Beams Under the Longitudinal Smoke Exhaust Mode

Previous studies on tunnel fires have primarily focused on tunnels with flat ceilings and lacked studies on tunnels with beams. The present study is predicated on a reduced-scale tunnel model with a beam structure. Through meticulous analysis of the effects of factors such as longitudinal ventilation velocity and beam dimensions, the study unveils the distribution pattern of ceiling temperatures under the longitudinal smoke exhaust mode. The findings suggest that the presence of beams can induce turbulence in the longitudinal ventilation airflow. It has been demonstrated that the magnitude of this phenomenon is directly proportional to the spacing of the beams. This results in fluctuations in the ceiling temperature rise close to the combustion zone. The smoke storage capacity of the open cavities formed between adjacent beams is significantly affected by the beam height, thereby influencing the overall temperature rise beneath the ceiling. The greater the beam height, the higher the overall ceiling temperature rise near the combustion zone, but the lower the ceiling temperature rise downstream of the fire source. A prediction model for the longitudinal decay of ceiling temperature downstream of the fire source in tunnels with beams has been obtained. This model is related to the dimensionless beam dimension.

Authors

Institutions

Publication Details

Journal
Fire
Published
2025-09-29
DOI
https://doi.org/10.3390/fire8100388
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Fire Temperature Pattern of Tunnels with Beams Under the Longitudinal Smoke Exhaust Mode

Shilin Feng, Yi Liang, Zihan Yu, Zhisheng Xu
Fire
Fire dynamics and safety research
article

Study on the Fire Temperature Pattern of Tunnels with Beams Under the Longitudinal Smoke Exhaust Mode

Shilin Feng, Yi Liang, Zihan Yu, Zhisheng Xu
article en

Abstract

Previous studies on tunnel fires have primarily focused on tunnels with flat ceilings and lacked studies on tunnels with beams. The present study is predicated on a reduced-scale tunnel model with a beam structure. Through meticulous analysis of the effects of factors such as longitudinal ventilation velocity and beam dimensions, the study unveils the distribution pattern of ceiling temperatures under the longitudinal smoke exhaust mode. The findings suggest that the presence of beams can induce turbulence in the longitudinal ventilation airflow. It has been demonstrated that the magnitude of this phenomenon is directly proportional to the spacing of the beams. This results in fluctuations in the ceiling temperature rise close to the combustion zone. The smoke storage capacity of the open cavities formed between adjacent beams is significantly affected by the beam height, thereby influencing the overall temperature rise beneath the ceiling. The greater the beam height, the higher the overall ceiling temperature rise near the combustion zone, but the lower the ceiling temperature rise downstream of the fire source. A prediction model for the longitudinal decay of ceiling temperature downstream of the fire source in tunnels with beams has been obtained. This model is related to the dimensionless beam dimension.

FireVol. 8(10)
Central South University (CN)
Central South University
Openalex Percentile: Top 67%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.