Study on the Replacement of Rail Vehicle Air-Conditioning Refrigerants with Low-GWP Refrigerant Mixtures
This study addresses the urgent demand for low-GWP refrigerant alternatives in rail vehicle air-conditioning systems by proposing a novel binary mixture, ZT01 (R13I1/R32 = 0.6/0.4 by mass), as a replacement for R407C. A comprehensive evaluation combining thermodynamic cycle modeling, refrigerant property analysis, and experimental validation shows that ZT01 delivers a coefficient of performance (COP) comparable to R407C, while providing a 45–49% improvement in volumetric cooling capacity, enabling smaller compressor displacement for the same cooling output, and reducing specific compressor work by 13–21%. In addition, ZT01 maintains a lower compression ratio, exhibits non-flammability, is compatible with POE lubricant, and has a GWP of only 308. Life Cycle Climate Performance (LCCP) analysis further indicates a 6.88% reduction in total carbon emissions and a 77.4% reduction in direct emissions compared to R407C, demonstrating that ZT01 is both technically feasible and environmentally sustainable for green retrofitting of rail vehicle HVAC systems.
Authors
- Xinge Chen (ORCID: https://orcid.org/0009-0007-7882-2038)
- Jianbin Zang
- Yuxin Zhang (ORCID: https://orcid.org/0009-0007-9230-6953)
- Cherie Lu
- Chun Song
Institutions
- Tongji University (CN)
Publication Details
- Journal
- Energies
- Published
- 2025-09-28
- DOI
- https://doi.org/10.3390/en18195164
- Primary Topic
- Refrigeration and Air Conditioning Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00