Rotating gold microwire electrode for the voltammetric detection of mercury and arsenic in shellfish

Monitoring mercury (Hg) and arsenic (As) in bivalve shellfish is crucial for ensuring food safety and protecting human health, given the bioaccumulation potential of these toxic contaminants. This study introduces a novel, low-cost, and highly sensitive electrochemical method for the determination of Hg and As in bivalve molluscs, leveraging a unique assembly that incorporates a gold micro-electrode. The electrode's design is characterised by its increased surface area resulting from the spherical geometry, enhancing sensitivity for trace metal detection. Further refinement is achieved through the integration of a conductive coupler, facilitating the electrode's rotation to augment analyte mass transport to the electrode surface, thereby improving the detection limits and overall analysis efficiency. The simplicity of the sensor assembly combined with its capacity for on-site and <i>in situ</i> application, sets a new benchmark for practicality in environmental monitoring tools. After pretreatment and conditioning of the substrate its ability to detect trace levels of As and Hg in certified reference materials and in real shellfish samples after microwave digestion was investigated. The repeatability, linearity, accuracy, and detection limit of the procedure were evaluated. For mercury and arsenic, a short 90 second deposition time resulted in detection limits of 0.3 μg L<sup>-1</sup> and 0.21 μg L<sup>-1</sup> and a linearity of 0.5 to 100 μg L<sup>-1</sup> and 1.0 to 100 μg L<sup>-1</sup>, respectively. Close agreement with stated values for a certified reference material verified the accuracy and reliability of the analysis.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay01018g
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rotating gold microwire electrode for the voltammetric detection of mercury and arsenic in shellfish

Denis McCrudden, Christopher McEleney, Wesley J. McCormick, Matthew McCole et al.
Analytical Methods
Electrochemical Analysis and Applications
article

Rotating gold microwire electrode for the voltammetric detection of mercury and arsenic in shellfish

Denis McCrudden, Christopher McEleney, Wesley J. McCormick, Matthew McCole, Eveline Düker
article en

Abstract

Monitoring mercury (Hg) and arsenic (As) in bivalve shellfish is crucial for ensuring food safety and protecting human health, given the bioaccumulation potential of these toxic contaminants. This study introduces a novel, low-cost, and highly sensitive electrochemical method for the determination of Hg and As in bivalve molluscs, leveraging a unique assembly that incorporates a gold micro-electrode. The electrode's design is characterised by its increased surface area resulting from the spherical geometry, enhancing sensitivity for trace metal detection. Further refinement is achieved through the integration of a conductive coupler, facilitating the electrode's rotation to augment analyte mass transport to the electrode surface, thereby improving the detection limits and overall analysis efficiency. The simplicity of the sensor assembly combined with its capacity for on-site and <i>in situ</i> application, sets a new benchmark for practicality in environmental monitoring tools. After pretreatment and conditioning of the substrate its ability to detect trace levels of As and Hg in certified reference materials and in real shellfish samples after microwave digestion was investigated. The repeatability, linearity, accuracy, and detection limit of the procedure were evaluated. For mercury and arsenic, a short 90 second deposition time resulted in detection limits of 0.3 μg L<sup>-1</sup> and 0.21 μg L<sup>-1</sup> and a linearity of 0.5 to 100 μg L<sup>-1</sup> and 1.0 to 100 μg L<sup>-1</sup>, respectively. Close agreement with stated values for a certified reference material verified the accuracy and reliability of the analysis.

Analytical MethodsVol. 17(39)
Letterkenny Institute of Technology (IE)
Openalex Percentile: Top 70%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Rotating gold microwire electrode for the voltammetric detection of mercury and arsenic in shellfish — Denis McCrudden, Christopher McEleney, et al. · Analytical Methods (2025) | TGRS Research Map | TGRS