Upper extremity strain in caregivers during enteral tube feeding of semi-solid nutrients to children requiring constant medical care: a simulated experiment focusing on the impact of new injection devices compliant with Standard No. ISO 80369-3

<i>Objectives.</i> Healthcare facilities provide semi-solid nutrients to children requiring enteral tube feeding. The introduction of a new injection device (NEW) with a different syringe-to-tube connector geometry from a pre-existing device (PRE) results in increased workload, and an increase in nurses developing hand pain is a concern. A simulated experiment was conducted to determine the impact on upper extremity strain due to the difference between NEW and PRE. <i>Methods.</i> Twelve nurses performed two injection tasks for one portion of semi-solid nutrients into a dummy gastrostomy using the NEW and PRE. Surface electromyograms were measured on the upper extremity. Task time was divided into sucking and extruding manipulations. Task time and mean myoelectric potentials were calculated for each manipulation and statistically compared between the NEW and PRE. Forces required to manipulate the syringe for semi-solid nutrient injection were estimated using fluid dynamic models. <i>Results.</i> Task time was significantly longer with the NEW. Myoelectric potentials for sucking manipulation were significantly higher with the NEW. Sucking force with the NEW was approximately twice that of the PRE. <i>Conclusion.</i> Sucking with the NEW placed a high strain on the caregiver's hand/wrist. The NEW is less appropriate for enteral tube feeding of semi-solid nutrients.

Authors

Institutions

Publication Details

Journal
International Journal of Occupational Safety and Ergonomics
Published
2025-09-29
DOI
https://doi.org/10.1080/10803548.2025.2550841
Primary Topic
Clinical Nutrition and Gastroenterology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Upper extremity strain in caregivers during enteral tube feeding of semi-solid nutrients to children requiring constant medical care: a simulated experiment focusing on the impact of new injection devices compliant with Standard No. ISO 80369-3

Masao Kumode, Teruyo Kitahara, Shin-ichi Shirahoshi, Akiko Nagae et al.
International Journal of Occupational Safety and Ergonomics
Clinical Nutrition and Gastroenterology
article

Upper extremity strain in caregivers during enteral tube feeding of semi-solid nutrients to children requiring constant medical care: a simulated experiment focusing on the impact of new injection devices compliant with Standard No. ISO 80369-3

Masao Kumode, Teruyo Kitahara, Shin-ichi Shirahoshi, Akiko Nagae, Hiroji Tsujimura, Kazushi Taoda, Satoko Henmi
article en

Abstract

<i>Objectives.</i> Healthcare facilities provide semi-solid nutrients to children requiring enteral tube feeding. The introduction of a new injection device (NEW) with a different syringe-to-tube connector geometry from a pre-existing device (PRE) results in increased workload, and an increase in nurses developing hand pain is a concern. A simulated experiment was conducted to determine the impact on upper extremity strain due to the difference between NEW and PRE. <i>Methods.</i> Twelve nurses performed two injection tasks for one portion of semi-solid nutrients into a dummy gastrostomy using the NEW and PRE. Surface electromyograms were measured on the upper extremity. Task time was divided into sucking and extruding manipulations. Task time and mean myoelectric potentials were calculated for each manipulation and statistically compared between the NEW and PRE. Forces required to manipulate the syringe for semi-solid nutrient injection were estimated using fluid dynamic models. <i>Results.</i> Task time was significantly longer with the NEW. Myoelectric potentials for sucking manipulation were significantly higher with the NEW. Sucking force with the NEW was approximately twice that of the PRE. <i>Conclusion.</i> Sucking with the NEW placed a high strain on the caregiver's hand/wrist. The NEW is less appropriate for enteral tube feeding of semi-solid nutrients.

International Journal of Occupational Safety and Ergonomics
Shiga University of Medical Science (JP), Biwako Gakuin University (JP), Bukkyo University (JP)
Openalex Percentile: Top 68%
Clinical Nutrition and Gastroenterology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.