Geometric, dosimetric and psychometric evaluation of three commercial AI software solutions for OAR auto-segmentation in head and neck radiotherapy

Contouring organs-at-risk (OARs) is a critical yet time-consuming step in head and neck (HaN) radiotherapy planning. Auto-segmentation methods have been widely studied, and commercial solutions are increasingly entering clinical use. However, their adoption warrants a comprehensive, multi-perspective evaluation. The purpose of this study is to compare three commercial artificial intelligence (AI) software solutions (Limbus, MIM and MVision) for HaN OAR auto-segmentation on a cohort of 10 computed tomography images with reference contours obtained from the public HaN-Seg dataset, from both observational (descriptive and empirical) and analytical (geometric, dosimetric and psychometric) perspectives. The observational evaluation included vendor questionnaires on technical specifications and radiographer feedback on usability. The analytical evaluation covered geometric (Dice similarity coefficient, DSC, and 95th percentile Hausdorff distance, HD95), dosimetric (dose constraint compliance, OAR priority-based analysis), and psychometric (5-point Likert scale) assessments. All software solutions covered a broad range of OARs. Overall geometric performance differences were relatively small (Limbus: 69.7% DSC, 5.0 mm HD95; MIM: 69.2% DSC, 5.6 mm HD95; MVision: 66.7% DSC, 5.3 mm HD95), however, statistically significant differences were observed for smaller structures such as the cochleae, optic chiasm, and pituitary and thyroid glands. Differences in dosimetric compliance were overall minor, with the lowest compliance observed for the oral cavity and submandibular glands. In terms of qualitative assessment, radiographers gave the highest average Likert rating to Limbus (3.9), followed by MVision (3.7) and MIM (3.5). With few exceptions, most software solutions produced good-quality AI-generated contours (Likert ratings ≥ 3), yet some editing should still be performed to reach clinical acceptability. Notable discrepancies were seen for the optic chiasm and in cases affected by mouth bites or dental artifacts. Importantly, no clear relationship emerged between geometric, dosimetric, and psychometric metrics, underscoring the need for a multi-perspective evaluation without shortcuts.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-09-29
DOI
https://doi.org/10.1038/s41598-025-18598-3
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Geometric, dosimetric and psychometric evaluation of three commercial AI software solutions for OAR auto-segmentation in head and neck radiotherapy

Susan Mercieca, C. Borg, Gašper Podobnik, Tomaž Vrtovec et al.
Scientific Reports
Advanced Radiotherapy Techniques
article

Geometric, dosimetric and psychometric evaluation of three commercial AI software solutions for OAR auto-segmentation in head and neck radiotherapy

Susan Mercieca, C. Borg, Gašper Podobnik, Tomaž Vrtovec, Carl James Debono
article en

Abstract

Contouring organs-at-risk (OARs) is a critical yet time-consuming step in head and neck (HaN) radiotherapy planning. Auto-segmentation methods have been widely studied, and commercial solutions are increasingly entering clinical use. However, their adoption warrants a comprehensive, multi-perspective evaluation. The purpose of this study is to compare three commercial artificial intelligence (AI) software solutions (Limbus, MIM and MVision) for HaN OAR auto-segmentation on a cohort of 10 computed tomography images with reference contours obtained from the public HaN-Seg dataset, from both observational (descriptive and empirical) and analytical (geometric, dosimetric and psychometric) perspectives. The observational evaluation included vendor questionnaires on technical specifications and radiographer feedback on usability. The analytical evaluation covered geometric (Dice similarity coefficient, DSC, and 95th percentile Hausdorff distance, HD95), dosimetric (dose constraint compliance, OAR priority-based analysis), and psychometric (5-point Likert scale) assessments. All software solutions covered a broad range of OARs. Overall geometric performance differences were relatively small (Limbus: 69.7% DSC, 5.0 mm HD95; MIM: 69.2% DSC, 5.6 mm HD95; MVision: 66.7% DSC, 5.3 mm HD95), however, statistically significant differences were observed for smaller structures such as the cochleae, optic chiasm, and pituitary and thyroid glands. Differences in dosimetric compliance were overall minor, with the lowest compliance observed for the oral cavity and submandibular glands. In terms of qualitative assessment, radiographers gave the highest average Likert rating to Limbus (3.9), followed by MVision (3.7) and MIM (3.5). With few exceptions, most software solutions produced good-quality AI-generated contours (Likert ratings ≥ 3), yet some editing should still be performed to reach clinical acceptability. Notable discrepancies were seen for the optic chiasm and in cases affected by mouth bites or dental artifacts. Importantly, no clear relationship emerged between geometric, dosimetric, and psychometric metrics, underscoring the need for a multi-perspective evaluation without shortcuts.

Scientific ReportsVol. 15(1)
University of Ljubljana (SI), University of Malta (MT)
Openalex Percentile: Top 64%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.