A 192-Channel 1D CNN-Based Neural Feature Extractor in 65nm CMOS for Brain-Machine Interfaces

We present a 192-channel 1D convolutional neural network (1D CNN) based neural feature extractor for Brain-Machine Interfaces (BMI) that achieves state-of-the-art decoding stability at $\mathbf{1.8\ \mu W}$ and 12801 $\mathbf{\mu m^{2}}$ per channel in 65nm CMOS technology. Our device is a fully configurable, scalable, area and power efficient solution that supports models with 2-8 feature layers and a total kernel length of up to 256. This architecture reduces caching requirements by $\mathbf{5}{\boldsymbol\times}$ over conventional computation schemes. Channels and layers are individually power-switchable to further optimize power efficiency for a given neural application. We introduce an on-chip model, FENet-66, that achieves the highest cross-validated decoding performance compared to all previously reported feature sets. We show that this model maintains superior stability over time using recorded data from tetraplegic human participants with spinal cord injury. Our features have 18% higher overall average cross-validated R2 decoding performance compared to Spiking Band Power (SBP), with 28% better performance during the 4th year. Our proposed architecture can also extract mean wavelet power features at low power and latency. We show that custom 1D-CNN kernels achieve 10% better performance compared to wavelet features while compressing the neural data stream by $\mathbf{38}{\boldsymbol\times}$. The models and hardware were validated in real time with a human subject in online closed-loop center-out cursor control experiments with micro-electrode arrays that were implanted for 6 years. Decoders using features generated with this work substantially improve the viability of long-term neural implants compared to other feature extraction methods currently present in low power BMI hardware.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Circuits and Systems
Published
2025-09-29
DOI
https://doi.org/10.1109/tbcas.2025.3615121
Primary Topic
CCD and CMOS Imaging Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 192-Channel 1D CNN-Based Neural Feature Extractor in 65nm CMOS for Brain-Machine Interfaces

Benyamin Haghi, Albert Huang, Steven Bulfer, Richard A. Andersen et al.
IEEE Transactions on Biomedical Circuits and Systems
CCD and CMOS Imaging Sensors
article

A 192-Channel 1D CNN-Based Neural Feature Extractor in 65nm CMOS for Brain-Machine Interfaces

Benyamin Haghi, Albert Huang, Steven Bulfer, Richard A. Andersen, Jorge Gámez, Volnei A. Pedroni, Azita Emami
article en

Abstract

We present a 192-channel 1D convolutional neural network (1D CNN) based neural feature extractor for Brain-Machine Interfaces (BMI) that achieves state-of-the-art decoding stability at $\mathbf{1.8\ \mu W}$ and 12801 $\mathbf{\mu m^{2}}$ per channel in 65nm CMOS technology. Our device is a fully configurable, scalable, area and power efficient solution that supports models with 2-8 feature layers and a total kernel length of up to 256. This architecture reduces caching requirements by $\mathbf{5}{\boldsymbol\times}$ over conventional computation schemes. Channels and layers are individually power-switchable to further optimize power efficiency for a given neural application. We introduce an on-chip model, FENet-66, that achieves the highest cross-validated decoding performance compared to all previously reported feature sets. We show that this model maintains superior stability over time using recorded data from tetraplegic human participants with spinal cord injury. Our features have 18% higher overall average cross-validated R2 decoding performance compared to Spiking Band Power (SBP), with 28% better performance during the 4th year. Our proposed architecture can also extract mean wavelet power features at low power and latency. We show that custom 1D-CNN kernels achieve 10% better performance compared to wavelet features while compressing the neural data stream by $\mathbf{38}{\boldsymbol\times}$. The models and hardware were validated in real time with a human subject in online closed-loop center-out cursor control experiments with micro-electrode arrays that were implanted for 6 years. Decoders using features generated with this work substantially improve the viability of long-term neural implants compared to other feature extraction methods currently present in low power BMI hardware.

IEEE Transactions on Biomedical Circuits and SystemsVol. 20(1)
California Institute of Technology (US)
Openalex Percentile: Top 74%
CCD and CMOS Imaging Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.