Detection and Localization of Acute Myocardial Infarction Using Branch-Reduced Convolutional Neural Network

Myocardial infarction can be life-threatening and needs to be detected accurately and quickly. In this paper, a branch-reduced network (BRN) is developed to detect and locate acute myocardial infarction (AMI) using single-lead electrocardiogram (ECG) signals and one-dimensional convolutional neural network. A grouping method for single-lead ECG signals is introduced to reduce the neural network size. A periodic feature-embedded convolutional block attention module is proposed to capture periodic features in the input ECG signals and improve AMI detection performance. The proposed model has achieved AMI detection sensitivity, specificity, and accuracy of 95.82%, 93.38%, and 95.16%, respectively. The AMI localization accuracy is 84.26%. The proposed model is of 28,863 trainable parameters, which is two orders of magnitude smaller than the number of trainable parameters in the related works. The compact network structure makes it possible to implement the proposed model on low-power handheld devices for emergency rooms, remote areas and developing countries.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3615312
Citations
1
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection and Localization of Acute Myocardial Infarction Using Branch-Reduced Convolutional Neural Network

John Q. Liu, Hanfei Shen
1 citations
IEEE Transactions on Instrumentation and Measurement
ECG Monitoring and Analysis
1.39
article

Detection and Localization of Acute Myocardial Infarction Using Branch-Reduced Convolutional Neural Network

John Q. Liu, Hanfei Shen
article en
1 citations

Abstract

Myocardial infarction can be life-threatening and needs to be detected accurately and quickly. In this paper, a branch-reduced network (BRN) is developed to detect and locate acute myocardial infarction (AMI) using single-lead electrocardiogram (ECG) signals and one-dimensional convolutional neural network. A grouping method for single-lead ECG signals is introduced to reduce the neural network size. A periodic feature-embedded convolutional block attention module is proposed to capture periodic features in the input ECG signals and improve AMI detection performance. The proposed model has achieved AMI detection sensitivity, specificity, and accuracy of 95.82%, 93.38%, and 95.16%, respectively. The AMI localization accuracy is 84.26%. The proposed model is of 28,863 trainable parameters, which is two orders of magnitude smaller than the number of trainable parameters in the related works. The compact network structure makes it possible to implement the proposed model on low-power handheld devices for emergency rooms, remote areas and developing countries.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Wayne State University (US)
Openalex Percentile: Top 14%
ECG Monitoring and Analysis
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detection and Localization of Acute Myocardial Infarction Using Branch-Reduced Convolutional Neural Network — John Q. Liu, Hanfei Shen · IEEE Transactions on Instrumentation and Measurement (2025) | TGRS Research Map | TGRS