Respiratory Motion-Robust Robotic Ultrasound Acquisitions via Vision-Haptic Fusion Control and 3-D Compensation

Robotic three-dimensional (3D) ultrasound (US) has demonstrated potential for reliable organ volume acquisition. However, respiratory motion during scanning critically reduces volume measurements accuracy, presenting a clinical limitation that affects not only cardiovascular but also all abdominal and spinal US diagnoses. To address this, we develop a robotic system integrating vision-based motion monitoring and interaction control for respiratory motion-robust US acquisition. The motion monitoring module constructs a self-calibrating predictive model that dynamically estimates respiratory motion and predicts the desired contact position. We further propose a vision-haptic fusion motion control framework that integrates predicted position feedback into the force-sensing admittance controller, equipping it with model-predictive capabilities. Afterward, to ensure accurate volume measurements, a compensation framework is presented to reduce respiratory motion-induced distortions by reconstructing in a relatively static frame and refining results using anatomical priors. Finally, the whole system was validated using a vessel phantom mounted on a six-axis platform simulating respiratory motion. Experimental results demonstrate that the robotic system ensures interaction stability (0.295 N force tracking accuracy) for US acquisition. The compensation framework significantly improve volume measurements accuracy, achieving a mean spatial distortion of 0.48 mm. These improvements highlight the robotic system’s capacity for stable US acquisition and accurate volume measurements across US diagnoses, which are crucial for diagnoses affected by respiratory motion.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3612625
Citations
1
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Respiratory Motion-Robust Robotic Ultrasound Acquisitions via Vision-Haptic Fusion Control and 3-D Compensation

Danqian Cao, Hongbin Liu, Guanglin Cao
1 citations
IEEE Transactions on Instrumentation and Measurement
Soft Robotics and Applications
0.67
article

Respiratory Motion-Robust Robotic Ultrasound Acquisitions via Vision-Haptic Fusion Control and 3-D Compensation

Danqian Cao, Hongbin Liu, Guanglin Cao
article en
1 citations

Abstract

Robotic three-dimensional (3D) ultrasound (US) has demonstrated potential for reliable organ volume acquisition. However, respiratory motion during scanning critically reduces volume measurements accuracy, presenting a clinical limitation that affects not only cardiovascular but also all abdominal and spinal US diagnoses. To address this, we develop a robotic system integrating vision-based motion monitoring and interaction control for respiratory motion-robust US acquisition. The motion monitoring module constructs a self-calibrating predictive model that dynamically estimates respiratory motion and predicts the desired contact position. We further propose a vision-haptic fusion motion control framework that integrates predicted position feedback into the force-sensing admittance controller, equipping it with model-predictive capabilities. Afterward, to ensure accurate volume measurements, a compensation framework is presented to reduce respiratory motion-induced distortions by reconstructing in a relatively static frame and refining results using anatomical priors. Finally, the whole system was validated using a vessel phantom mounted on a six-axis platform simulating respiratory motion. Experimental results demonstrate that the robotic system ensures interaction stability (0.295 N force tracking accuracy) for US acquisition. The compensation framework significantly improve volume measurements accuracy, achieving a mean spatial distortion of 0.48 mm. These improvements highlight the robotic system’s capacity for stable US acquisition and accurate volume measurements across US diagnoses, which are crucial for diagnoses affected by respiratory motion.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Chinese Academy of Sciences (CN), Institute of Automation (CN), Chinese University of Hong Kong, Shenzhen (CN), Institut de Recherche et d’Innovation (FR)
Openalex Percentile: Top 26%
Soft Robotics and Applications
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.