Video Object Segmentation with Optimal Frame Auto-selection Based on Prior Knowledge for Midbrain Assessment in Transcranial Ultrasound

Transcranial sonography (TCS) provides a non-invasive means of assessing movement disorders such as Parkinson's disease (PD). However, current TCS-based evaluations rely heavily on manual operation by experienced physicians, making the process time-consuming and physician-dependent. For the first time, we aimed to develop a hybrid pipeline for real-time video object segmentation (VOS) and automatic optimal frame selection. Eighty-three standardized TCS real-time data comprising 1,992 midbrain frames from Beijing Tiantan Hospital were collected. We adopted three state-of-the-art VOS models (STCN, RDE-VOS, and XMEM) and incorporated anatomical priors to guide optimal frame selection. Specifically, we leveraged the anatomical trend of midbrain morphology to estimate the midbrain radius at the optimal frame and selected the frame where the VOS-segmented midbrain best matched this estimate. The XMEM-based pipeline achieved high segmentation performance (Jaccard: 0.85, Boundary Accuracy: 0.95, Dice: 0.92) and optimal frame selection (Distance: 4.87; Jaccard: 0.92), with efficiency (51.05 FPS, 0.56 s/patient, 661.55 MB). Subgroup analyses confirmed robustness across image quality and PD conditions. Assessment of a junior physician's selection suggests potential to reduce the expertise gap in optimal frame selection. The proposed hybrid pipeline offers an automated tool for midbrain assessment using TCS, which may help reduce physicians' workload and minimize subjectivity, particularly supporting junior physicians in mitigating the expertise-demanding nature of TCS. This approach may serve as a foundation for more promising TCS-based assessments in the future, contributing to broader adoption of non-invasive ultrasound techniques in PD evaluation.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2025-01-01
DOI
https://doi.org/10.1109/jbhi.2025.3614160
Primary Topic
Infrared Thermography in Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Video Object Segmentation with Optimal Frame Auto-selection Based on Prior Knowledge for Midbrain Assessment in Transcranial Ultrasound

Xin Sun, Saikit Lam, Shuai Li, Yu Sun et al.
IEEE Journal of Biomedical and Health Informatics
Infrared Thermography in Medicine
article

Video Object Segmentation with Optimal Frame Auto-selection Based on Prior Knowledge for Midbrain Assessment in Transcranial Ultrasound

Xin Sun, Saikit Lam, Shuai Li, Yu Sun, Fangxian Li, Xinyi Wang, Wei Zhang, Yong‐Ping Zheng, Jiannong Cao, Xiao-Ming Wu, Hongyu Kang, Chao Hou
article en

Abstract

Transcranial sonography (TCS) provides a non-invasive means of assessing movement disorders such as Parkinson's disease (PD). However, current TCS-based evaluations rely heavily on manual operation by experienced physicians, making the process time-consuming and physician-dependent. For the first time, we aimed to develop a hybrid pipeline for real-time video object segmentation (VOS) and automatic optimal frame selection. Eighty-three standardized TCS real-time data comprising 1,992 midbrain frames from Beijing Tiantan Hospital were collected. We adopted three state-of-the-art VOS models (STCN, RDE-VOS, and XMEM) and incorporated anatomical priors to guide optimal frame selection. Specifically, we leveraged the anatomical trend of midbrain morphology to estimate the midbrain radius at the optimal frame and selected the frame where the VOS-segmented midbrain best matched this estimate. The XMEM-based pipeline achieved high segmentation performance (Jaccard: 0.85, Boundary Accuracy: 0.95, Dice: 0.92) and optimal frame selection (Distance: 4.87; Jaccard: 0.92), with efficiency (51.05 FPS, 0.56 s/patient, 661.55 MB). Subgroup analyses confirmed robustness across image quality and PD conditions. Assessment of a junior physician's selection suggests potential to reduce the expertise gap in optimal frame selection. The proposed hybrid pipeline offers an automated tool for midbrain assessment using TCS, which may help reduce physicians' workload and minimize subjectivity, particularly supporting junior physicians in mitigating the expertise-demanding nature of TCS. This approach may serve as a foundation for more promising TCS-based assessments in the future, contributing to broader adoption of non-invasive ultrasound techniques in PD evaluation.

IEEE Journal of Biomedical and Health InformaticsVol. PP
Hong Kong Polytechnic University (HK), Capital Medical University (CN), Beijing Tian Tan Hospital (CN)
Openalex Percentile: Top 60%
Infrared Thermography in Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.