Dynamic PMU Configuration for Stealthy Multi-Snapshot FDIA Mitigation: Enhancing Security in Hybrid-Measurement-Based State Estimation in Power Systems

Modern power systems have evolved into cyber-physical power systems (CPPSs) requiring high-resolution spatial-temporal state awareness, driving the adoption of hybrid measurement-based state estimation (SE). However, such advancements introduce heightened cybersecurity requirements that demand systematic investigations from adversarial perspectives. This paper establishes a comprehensive attacker‒defender framework with dual contributions. From the attacker's perspective, this paper proposes a multi-snapshot coordinated false data injection attack (MS-FDIA) strategy against hybrid measurement-based SE. The proposed attack model can effectively bypass both hybrid measurement synchronization checks and temporal data anomaly detection mechanisms, thereby achieving enhanced stealth and operational impact. From the defender’s perspective, this paper develops a dynamic trusted phasor measurement unit (PMU) configuration scheme that adaptively reconfigures secure measurement matrix subsets against evolving multistage attacks. The defense mechanism is solved through two complementary approaches: a numerical algorithm based on matrix row transformations and a deep reinforcement learning (DRL)-based optimization method with temporal awareness. Comprehensive case studies on different standard test systems demonstrate the improved MS-FDIA's evasion capabilities and the defense scheme's effectiveness, and the test results reveal the matrix transformation algorithm's superiority in small-scale systems versus DRL's scalability advantages for large networks.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Smart Grid
Published
2025-09-29
DOI
https://doi.org/10.1109/tsg.2025.3615645
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic PMU Configuration for Stealthy Multi-Snapshot FDIA Mitigation: Enhancing Security in Hybrid-Measurement-Based State Estimation in Power Systems

Yi Tang, Yujian Ye, Jianxiong Hu, Shutan Wu et al.
IEEE Transactions on Smart Grid
Smart Grid Security and Resilience
article

Dynamic PMU Configuration for Stealthy Multi-Snapshot FDIA Mitigation: Enhancing Security in Hybrid-Measurement-Based State Estimation in Power Systems

Yi Tang, Yujian Ye, Jianxiong Hu, Shutan Wu, Qi Wang
article en

Abstract

Modern power systems have evolved into cyber-physical power systems (CPPSs) requiring high-resolution spatial-temporal state awareness, driving the adoption of hybrid measurement-based state estimation (SE). However, such advancements introduce heightened cybersecurity requirements that demand systematic investigations from adversarial perspectives. This paper establishes a comprehensive attacker‒defender framework with dual contributions. From the attacker's perspective, this paper proposes a multi-snapshot coordinated false data injection attack (MS-FDIA) strategy against hybrid measurement-based SE. The proposed attack model can effectively bypass both hybrid measurement synchronization checks and temporal data anomaly detection mechanisms, thereby achieving enhanced stealth and operational impact. From the defender’s perspective, this paper develops a dynamic trusted phasor measurement unit (PMU) configuration scheme that adaptively reconfigures secure measurement matrix subsets against evolving multistage attacks. The defense mechanism is solved through two complementary approaches: a numerical algorithm based on matrix row transformations and a deep reinforcement learning (DRL)-based optimization method with temporal awareness. Comprehensive case studies on different standard test systems demonstrate the improved MS-FDIA's evasion capabilities and the defense scheme's effectiveness, and the test results reveal the matrix transformation algorithm's superiority in small-scale systems versus DRL's scalability advantages for large networks.

IEEE Transactions on Smart GridVol. 17(1)
Wenzhou University (CN), Southeast University (CN)
Openalex Percentile: Top 67%
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dynamic PMU Configuration for Stealthy Multi-Snapshot FDIA Mitigation: Enhancing Security in Hybrid-Measurement-Based State Estimation in Power Systems — Yi Tang, Yujian Ye, et al. · IEEE Transactions on Smart Grid (2025) | TGRS Research Map | TGRS