Evaluation of a PET Insert for Trimodal Imaging: A Step Towards PET/MRI-Guided Focused Ultrasound

Combining Positron Emission Tomography (PET) with Magnetic Resonance Imaging (MRI) and Focused Ultrasound (FUS) has emerged as a promising hybrid technique in the medical imaging field. Despite the potential benefits of using simultaneous PET and MRI acquisitions to monitor therapeutic effects and ensure precision and safety during FUS applications, no commercial or academic PET/MRI-guided FUS system (referred in the following as trimodal PET-MRI-FUS) exists. This work presents the design and evaluation of a preclinical PET insert for simultaneous operation with MRI and FUS systems. The proposed PET insert is based on monolithic LYSO crystals arranged in two octagonal rings that define inner and outer diameters of 72 mm and 114 mm, respectively, with an axial length of 67 mm. The system performance was evaluated according to the NEMA NU 4 2008 protocol. It achieves a uniform spatial resolution of ~0.9 mm along the whole PET Field of View (FOV) when enabling Depth of Interaction (DOI) capabilities. Moreover, we found a sensitivity peak of 3.8% for an energy window of 255-766 keV and a peak noise equivalent count rate peak of 80 kcps at an activity of 19 MBq. The compatibility of the PET insert with both low-and high-field MRI systems, as well as with custom and commercially available FUS devices, was studied using phantoms and in vivo experiments, respectively. The results of the trimodal tests have proven that the PET insert works simultaneously with both MRI and FUS systems.

Authors

Publication Details

Journal
IEEE Transactions on Radiation and Plasma Medical Sciences
Published
2025-01-01
DOI
https://doi.org/10.1109/trpms.2025.3615467
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a PET Insert for Trimodal Imaging: A Step Towards PET/MRI-Guided Focused Ultrasound

Antonio J. González, Joseph V. Rispoli, Eduardo Pallás, Irene Torres-Espallardo et al.
IEEE Transactions on Radiation and Plasma Medical Sciences
Radiomics and Machine Learning in Medical Imaging
article

Evaluation of a PET Insert for Trimodal Imaging: A Step Towards PET/MRI-Guided Focused Ultrasound

Antonio J. González, Joseph V. Rispoli, Eduardo Pallás, Irene Torres-Espallardo, Santiago Jiménez-Serrano, María José Rodríguez-Álvarez, Joseba Alonso, José Miguel Algarín, Rubén Bosch, Francisco Camarena, Alicia Carrión, Francis Loignon-Houle, Andrea Gonzalez‐Montoro, Zehra E.F. Demir, Jonathan Sachs, Teresa Guallart‐Naval, Michael Hoch, Jiabao He, Marta Freire, Nicholas J. Tustison, J. Benlloch, Natasha Sheybani, Mark B. Williams, Stuart S. Berr, Thomas Sherlock, Stefanyda Maslova, A. González-Tamarit, J. L. Alonso-Ramos, F. Lopez-Berenguer, Luis Vidal, Juan J. Rodríguez-García, D. Andrés, Andrew T Thede
article en

Abstract

Combining Positron Emission Tomography (PET) with Magnetic Resonance Imaging (MRI) and Focused Ultrasound (FUS) has emerged as a promising hybrid technique in the medical imaging field. Despite the potential benefits of using simultaneous PET and MRI acquisitions to monitor therapeutic effects and ensure precision and safety during FUS applications, no commercial or academic PET/MRI-guided FUS system (referred in the following as trimodal PET-MRI-FUS) exists. This work presents the design and evaluation of a preclinical PET insert for simultaneous operation with MRI and FUS systems. The proposed PET insert is based on monolithic LYSO crystals arranged in two octagonal rings that define inner and outer diameters of 72 mm and 114 mm, respectively, with an axial length of 67 mm. The system performance was evaluated according to the NEMA NU 4 2008 protocol. It achieves a uniform spatial resolution of ~0.9 mm along the whole PET Field of View (FOV) when enabling Depth of Interaction (DOI) capabilities. Moreover, we found a sensitivity peak of 3.8% for an energy window of 255-766 keV and a peak noise equivalent count rate peak of 80 kcps at an activity of 19 MBq. The compatibility of the PET insert with both low-and high-field MRI systems, as well as with custom and commercially available FUS devices, was studied using phantoms and in vivo experiments, respectively. The results of the trimodal tests have proven that the PET insert works simultaneously with both MRI and FUS systems.

IEEE Transactions on Radiation and Plasma Medical Sciences
Openalex Percentile: Top 60%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.