Accuracy evaluation of multibeam echo sounder systems

To ensure the quality of multibeam bathymetric data, it is essential to carry out a rigorous accuracy assessment of the processed survey results. Although many domestic standards advocate using the root mean square error derived from discrepancies at primary cross-check points as a means of evaluation, this approach has shown significant sensitivity to water depth, often failing to objectively reflect the overall measurement accuracy. Consequently, its effectiveness in representing survey quality is limited. To address this issue and provide a more comprehensive reflection of multibeam survey accuracy, this study proposes a combined assessment method based on both internal and external consistency metrics. Using the Norbit400L multibeam echo sounder system as a case study, we evaluate the system's accuracy through comparative analyses of internally and externally consistent depth measurements. Field validation was conducted in the artificial island and tunnel section of the Hong Kong-Zhuhai-Macao Bridge. The proposed methodology offers a valuable reference for determining accuracy specifications of other multibeam systems.

Authors

Institutions

Publication Details

Published
2025-09-29
DOI
https://doi.org/10.1117/12.3082351
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy evaluation of multibeam echo sounder systems

Yang Li, Xu Xiao, Xu Lin
Flow Measurement and Analysis
article

Accuracy evaluation of multibeam echo sounder systems

Yang Li, Xu Xiao, Xu Lin
article en

Abstract

To ensure the quality of multibeam bathymetric data, it is essential to carry out a rigorous accuracy assessment of the processed survey results. Although many domestic standards advocate using the root mean square error derived from discrepancies at primary cross-check points as a means of evaluation, this approach has shown significant sensitivity to water depth, often failing to objectively reflect the overall measurement accuracy. Consequently, its effectiveness in representing survey quality is limited. To address this issue and provide a more comprehensive reflection of multibeam survey accuracy, this study proposes a combined assessment method based on both internal and external consistency metrics. Using the Norbit400L multibeam echo sounder system as a case study, we evaluate the system's accuracy through comparative analyses of internally and externally consistent depth measurements. Field validation was conducted in the artificial island and tunnel section of the Hong Kong-Zhuhai-Macao Bridge. The proposed methodology offers a valuable reference for determining accuracy specifications of other multibeam systems.

China Shipbuilding Industry Corporation (China) (CN)
Openalex Percentile: Top 70%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.