Simple Detection of Culturable <i>Legionella pneumophila</i> in Cooling Tower Water Samples using Legiolert

We compared the results of Legionella pneumophila detection in cooling tower water samples using Legiolert and the conventional plate culture method. Both 1 mL and 10 mL volumes of cooling tower water samples were analyzed using Legiolert. The concordance rate of the Legiolert-1 mL test and the plate culture method was 86.7%. The Legiolert-10 mL test and the plate culture method showed 85.0% concordance. Legiolert would be effective for hygiene control in cooling towers because it can easily detect viable L. pneumophila in cooling tower water and produces results comparable to the conventional plate culture method.

Authors

Institutions

Publication Details

Journal
Journal of Microorganism Control
Published
2025-01-01
DOI
https://doi.org/10.4265/jmc.30.3_99
Primary Topic
Legionella and Acanthamoeba research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simple Detection of Culturable Legionella pneumophila in Cooling Tower Water Samples using Legiolert

HIRONORI HATTORI, T. Kaneko, H. Nakata, Masahiro Katada et al.
Journal of Microorganism Control
Legionella and Acanthamoeba research
article

Simple Detection of Culturable Legionella pneumophila in Cooling Tower Water Samples using Legiolert

HIRONORI HATTORI, T. Kaneko, H. Nakata, Masahiro Katada, Masaki Okamoto, Hiroaki Inoue, MASATO SENSUI
article en

Abstract

We compared the results of Legionella pneumophila detection in cooling tower water samples using Legiolert and the conventional plate culture method. Both 1 mL and 10 mL volumes of cooling tower water samples were analyzed using Legiolert. The concordance rate of the Legiolert-1 mL test and the plate culture method was 86.7%. The Legiolert-10 mL test and the plate culture method showed 85.0% concordance. Legiolert would be effective for hygiene control in cooling towers because it can easily detect viable L. pneumophila in cooling tower water and produces results comparable to the conventional plate culture method.

Journal of Microorganism ControlVol. 30(3)
Yokkaichi University (JP), Pioneer (United States) (US), Sanyo (Japan) (JP), Fundamentproekt (Russia) (RU), a.i. solutions (United States) (US), Maruishi Pharmaceutical (Japan) (JP), Sun Chemical (United States) (US)
Openalex Percentile: Top 77%
Legionella and Acanthamoeba research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simple Detection of Culturable <i>Legionella pneumophila</i> in Cooling Tower Water Samples using Legiolert — HIRONORI HATTORI, T. Kaneko, et al. · Journal of Microorganism Control (2025) | TGRS Research Map | TGRS