Preparation of 2D Graphitic Carbon Nitride/Redox Polymer Composite Modified Electrode for Selective Detection of Epinephrine in Real-World Samples

The development of an efficient, simple, and cost-effective electrode material for accurately measuring the activity of neurotransmitters in the human body has become a significant focus in the research community. In this context, we have synthesized a novel composite of polyluminol (PLUM) coated graphitic carbon nitride (GCN) for the detection of epinephrine (Epi), also known as adrenaline. We employed various spectroscopic and analytical methods to analyze the crystalline and structural characteristics of both GCN and PLUM/GCN. The PLUM/GCN modified glassy carbon electrode shows excellent electrocatalytic properties for Epi detection. Notably, this sensor has a lowest detection limit of 0.00142 μM and a wide linear range of detection from 0.05 to 200 μM. The proposed PLUM/GCN sensor demonstrates good stability, strong repeatability, and limited selectivity in the presence of common interfering compounds. Furthermore, the PLUM/GCN sensor showed recovery rates between 89.20 and 106.90% for detecting Epi in spiked adrenaline injection samples and human bodily fluids, such as human blood serum and urine. This demonstrates the potential applicability of the proposed sensor in real-world samples.

Authors

Publication Details

Journal
ECS Sensors Plus
Published
2025-09-29
DOI
https://doi.org/10.1149/2754-2726/ae0cd8
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preparation of 2D Graphitic Carbon Nitride/Redox Polymer Composite Modified Electrode for Selective Detection of Epinephrine in Real-World Samples

Ashok Kumar Sundramoorthy, Sandeep Arya, Raji Atchudan, Gokul Sridharan et al.
1 citations
ECS Sensors Plus
Electrochemical sensors and biosensors
0.73
article

Preparation of 2D Graphitic Carbon Nitride/Redox Polymer Composite Modified Electrode for Selective Detection of Epinephrine in Real-World Samples

Ashok Kumar Sundramoorthy, Sandeep Arya, Raji Atchudan, Gokul Sridharan, Surendra H. Mahadevegowda, Surendar Balu
article en
1 citations

Abstract

The development of an efficient, simple, and cost-effective electrode material for accurately measuring the activity of neurotransmitters in the human body has become a significant focus in the research community. In this context, we have synthesized a novel composite of polyluminol (PLUM) coated graphitic carbon nitride (GCN) for the detection of epinephrine (Epi), also known as adrenaline. We employed various spectroscopic and analytical methods to analyze the crystalline and structural characteristics of both GCN and PLUM/GCN. The PLUM/GCN modified glassy carbon electrode shows excellent electrocatalytic properties for Epi detection. Notably, this sensor has a lowest detection limit of 0.00142 μM and a wide linear range of detection from 0.05 to 200 μM. The proposed PLUM/GCN sensor demonstrates good stability, strong repeatability, and limited selectivity in the presence of common interfering compounds. Furthermore, the PLUM/GCN sensor showed recovery rates between 89.20 and 106.90% for detecting Epi in spiked adrenaline injection samples and human bodily fluids, such as human blood serum and urine. This demonstrates the potential applicability of the proposed sensor in real-world samples.

ECS Sensors PlusVol. 4(4)
Openalex Percentile: Top 23%
Electrochemical sensors and biosensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.