Development and evaluation of a novel capillary blood collection method for decentralized therapeutic drug monitoring using the True Dose kit

Interindividual variability in epirubicin exposure limits the efficacy of standard chemotherapy dosing based on body surface area (BSA) in breast cancer. This study evaluated a novel liquid-based capillary microsampling technology, True Dose<sup>®</sup>, to enable decentralized therapeutic drug monitoring (TDM). It integrates internal standards (IS) at the blood collection point, enabling the immediate precipitation of proteins and stabilization of analytes. Analytical validation using liquid chromatography-tandem mass spectrometry (LC-MS/MS) showed that epirubicin signal responses from capillary samples corresponded with those from conventional venous samples, achieving R² values of ≥ 0.99. Intra-assay coefficient of variation (CV%) improved over time, decreasing from up to 18.6% at T0 to ≤ 11% from Day 3 onward, consistent with time-dependent matrix equilibration and improved extraction efficiency. Pre- and post-activation stability studies confirmed analyte integrity for up to 14 days at ambient temperatures. Hematocrit levels ranging from 7 to 18 g/dL showed no more than 17% signal variation, confirming matrix stability. In a clinical substudy involving 4 early-stage breast cancer patients, capillary-collected samples (n = 4 Cap-TD) yielded epirubicin/doxorubicin ratios that differed by no more than 15% from venous-derived samples; interpretation is limited by the small sample size. The findings support the feasibility of the True Dose<sup>®</sup> system as a method for decentralized TDM of anthracycline (epirubicin) chemotherapy. The technology demonstrated analyte stability under room temperature storage for up to 14 days, time-dependent improvement in analytical precision, and minimal hematocrit bias, warranting further investigation in a broader clinical setting.Clinical trial identification: EudraCT 2017-000641-44 (registered 27 Feb 2017); EUCT 2024-514818-12-00 (CTIS, transitioned from EudraCT).

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-09-29
DOI
https://doi.org/10.1038/s41598-025-20951-5
Citations
1
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and evaluation of a novel capillary blood collection method for decentralized therapeutic drug monitoring using the True Dose kit

Antonio Checa, Oscar P. B. Wiklander, Per Rydberg, Elham Hedayati et al.
1 citations
Scientific Reports
Microfluidic and Capillary Electrophoresis Applications
0.67
article

Development and evaluation of a novel capillary blood collection method for decentralized therapeutic drug monitoring using the True Dose kit

Antonio Checa, Oscar P. B. Wiklander, Per Rydberg, Elham Hedayati, S. Chiara, Nektarios Komninos
article en
1 citations

Abstract

Interindividual variability in epirubicin exposure limits the efficacy of standard chemotherapy dosing based on body surface area (BSA) in breast cancer. This study evaluated a novel liquid-based capillary microsampling technology, True Dose<sup>®</sup>, to enable decentralized therapeutic drug monitoring (TDM). It integrates internal standards (IS) at the blood collection point, enabling the immediate precipitation of proteins and stabilization of analytes. Analytical validation using liquid chromatography-tandem mass spectrometry (LC-MS/MS) showed that epirubicin signal responses from capillary samples corresponded with those from conventional venous samples, achieving R² values of ≥ 0.99. Intra-assay coefficient of variation (CV%) improved over time, decreasing from up to 18.6% at T0 to ≤ 11% from Day 3 onward, consistent with time-dependent matrix equilibration and improved extraction efficiency. Pre- and post-activation stability studies confirmed analyte integrity for up to 14 days at ambient temperatures. Hematocrit levels ranging from 7 to 18 g/dL showed no more than 17% signal variation, confirming matrix stability. In a clinical substudy involving 4 early-stage breast cancer patients, capillary-collected samples (n = 4 Cap-TD) yielded epirubicin/doxorubicin ratios that differed by no more than 15% from venous-derived samples; interpretation is limited by the small sample size. The findings support the feasibility of the True Dose<sup>®</sup> system as a method for decentralized TDM of anthracycline (epirubicin) chemotherapy. The technology demonstrated analyte stability under room temperature storage for up to 14 days, time-dependent improvement in analytical precision, and minimal hematocrit bias, warranting further investigation in a broader clinical setting.Clinical trial identification: EudraCT 2017-000641-44 (registered 27 Feb 2017); EUCT 2024-514818-12-00 (CTIS, transitioned from EudraCT).

Scientific ReportsVol. 15(1)
Karolinska University Hospital (SE), Karolinska Institutet (SE), Stockholm South General Hospital (SE), True (United States) (US)
Karolinska Institutet
Openalex Percentile: Top 26%
Microfluidic and Capillary Electrophoresis Applications
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.