Transformer Enabled Half Z-spectrum Sampling B <sub>0</sub> Inhomogeneity Correction for GluCEST and NOE MRI

<i>Purpose</i>. Chemical Exchange Saturation Transfer (CEST) MRI relies on multiple saturation offsets to correct B<sub>0</sub> inhomogeneity-induced quantification errors at the cost of a prolonged scan time. We previously developed a deep learning-based method for B<sub>0</sub> inhomogeneity correction in Glutamate-weighted CEST (GluCEST) using a parsimonious number of Z-spectrum offset images, which can significantly reduce scan time and provide better correction quality. In this study, we propose a Transformer-based model that achieves B<sub>0</sub> correction using only downfield Z-spectrum offset images, further reducing scan time by about 50%. <i>Methods</i>. B<sub>0</sub> correction was performed separately for the positive and negative sides of the Z-spectrum using reduced saturation offset acquisitions. We constructed distinct Swin transformer networks for each side, training them to learn the nonlinear mapping from a limited number of GluCEST images at various frequencies on the positive side to the specific 3 ppm points where GluCEST peaks. A similar methodology was applied to NOE CEST imaging, optimizing each network to effectively handle the unique characteristics of each spectrum side. <i>Results</i>. The Transformer-based models significantly outperformed the previous deep learning methods both visually and quantitatively. By limiting inputs to only the positive Z-spectrum offsets, we achieved a 50% reduction in data acquisition time compared with previous deep learning approaches while maintaining B<sub>0</sub> inhomogeneity correction accuracy. <i>Conclusion</i>. Efficient B<sub>0</sub> inhomogeneity correction in GluCEST and NOE MRI can be achieved by using a select number of offset images from the downfield Z-spectrum, reducing the acquisition time by over 80%. The proposed transformer-based model demonstrates superior performance over traditional convolutional neural networks, offering a robust and efficient solution for performing CEST MRI in clinical practice.

Authors

Institutions

Publication Details

Journal
Chemical & Biomedical Imaging
Published
2025-09-12
DOI
https://doi.org/10.1021/cbmi.5c00071
Citations
1
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transformer Enabled Half Z-spectrum Sampling B 0 Inhomogeneity Correction for GluCEST and NOE MRI

Ravinder Reddy, John A. Detre, Anshuman Swain, Dushyant Kumar et al.
1 citations
Chemical & Biomedical Imaging
Advanced MRI Techniques and Applications
1.36
article

Transformer Enabled Half Z-spectrum Sampling B 0 Inhomogeneity Correction for GluCEST and NOE MRI

Ravinder Reddy, John A. Detre, Anshuman Swain, Dushyant Kumar, Neil E. Wilson, Paul S. Jacobs, Yiran Li, Ze Wang
article en
1 citations

Abstract

<i>Purpose</i>. Chemical Exchange Saturation Transfer (CEST) MRI relies on multiple saturation offsets to correct B<sub>0</sub> inhomogeneity-induced quantification errors at the cost of a prolonged scan time. We previously developed a deep learning-based method for B<sub>0</sub> inhomogeneity correction in Glutamate-weighted CEST (GluCEST) using a parsimonious number of Z-spectrum offset images, which can significantly reduce scan time and provide better correction quality. In this study, we propose a Transformer-based model that achieves B<sub>0</sub> correction using only downfield Z-spectrum offset images, further reducing scan time by about 50%. <i>Methods</i>. B<sub>0</sub> correction was performed separately for the positive and negative sides of the Z-spectrum using reduced saturation offset acquisitions. We constructed distinct Swin transformer networks for each side, training them to learn the nonlinear mapping from a limited number of GluCEST images at various frequencies on the positive side to the specific 3 ppm points where GluCEST peaks. A similar methodology was applied to NOE CEST imaging, optimizing each network to effectively handle the unique characteristics of each spectrum side. <i>Results</i>. The Transformer-based models significantly outperformed the previous deep learning methods both visually and quantitatively. By limiting inputs to only the positive Z-spectrum offsets, we achieved a 50% reduction in data acquisition time compared with previous deep learning approaches while maintaining B<sub>0</sub> inhomogeneity correction accuracy. <i>Conclusion</i>. Efficient B<sub>0</sub> inhomogeneity correction in GluCEST and NOE MRI can be achieved by using a select number of offset images from the downfield Z-spectrum, reducing the acquisition time by over 80%. The proposed transformer-based model demonstrates superior performance over traditional convolutional neural networks, offering a robust and efficient solution for performing CEST MRI in clinical practice.

Chemical & Biomedical ImagingVol. 4(2)
University of Maryland, Baltimore (US), California University of Pennsylvania (US)
Openalex Percentile: Top 15%
Advanced MRI Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.