Transformer Enabled Half Z-spectrum Sampling B <sub>0</sub> Inhomogeneity Correction for GluCEST and NOE MRI
<i>Purpose</i>. Chemical Exchange Saturation Transfer (CEST) MRI relies on multiple saturation offsets to correct B<sub>0</sub> inhomogeneity-induced quantification errors at the cost of a prolonged scan time. We previously developed a deep learning-based method for B<sub>0</sub> inhomogeneity correction in Glutamate-weighted CEST (GluCEST) using a parsimonious number of Z-spectrum offset images, which can significantly reduce scan time and provide better correction quality. In this study, we propose a Transformer-based model that achieves B<sub>0</sub> correction using only downfield Z-spectrum offset images, further reducing scan time by about 50%. <i>Methods</i>. B<sub>0</sub> correction was performed separately for the positive and negative sides of the Z-spectrum using reduced saturation offset acquisitions. We constructed distinct Swin transformer networks for each side, training them to learn the nonlinear mapping from a limited number of GluCEST images at various frequencies on the positive side to the specific 3 ppm points where GluCEST peaks. A similar methodology was applied to NOE CEST imaging, optimizing each network to effectively handle the unique characteristics of each spectrum side. <i>Results</i>. The Transformer-based models significantly outperformed the previous deep learning methods both visually and quantitatively. By limiting inputs to only the positive Z-spectrum offsets, we achieved a 50% reduction in data acquisition time compared with previous deep learning approaches while maintaining B<sub>0</sub> inhomogeneity correction accuracy. <i>Conclusion</i>. Efficient B<sub>0</sub> inhomogeneity correction in GluCEST and NOE MRI can be achieved by using a select number of offset images from the downfield Z-spectrum, reducing the acquisition time by over 80%. The proposed transformer-based model demonstrates superior performance over traditional convolutional neural networks, offering a robust and efficient solution for performing CEST MRI in clinical practice.
Authors
- Ravinder Reddy (ORCID: https://orcid.org/0000-0003-4580-2392)
- John A. Detre (ORCID: https://orcid.org/0000-0002-8115-6343)
- Anshuman Swain (ORCID: https://orcid.org/0000-0002-0257-8610)
- Dushyant Kumar (ORCID: https://orcid.org/0000-0002-1617-6399)
- Neil E. Wilson (ORCID: https://orcid.org/0009-0002-7766-2929)
- Paul S. Jacobs (ORCID: https://orcid.org/0000-0003-3566-4010)
- Yiran Li (ORCID: https://orcid.org/0000-0002-5502-2106)
- Ze Wang (ORCID: https://orcid.org/0000-0002-8339-5567)
Institutions
- University of Maryland, Baltimore (US)
- California University of Pennsylvania (US)
Publication Details
- Journal
- Chemical & Biomedical Imaging
- Published
- 2025-09-12
- DOI
- https://doi.org/10.1021/cbmi.5c00071
- Citations
- 1
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 1.36