Microscopic characterization of the anisotropic mechanical behavior of human linea alba and anterior rectus sheath: contributions of collagen and elastin

• The study focuses on the uniaxial mechanical properties of human linea alba and anterior rectus sheath with two-photon microscopy. • The anterior rectus sheath’s collagen fibers orientations strongly correlates with the tissue’s apparent stiffness. • Elastin is more abundant in the linea alba, consistent with its strain-accommodation role. • These findings support the design of patient-specific bioinspired implants replicating the mechanical conditions for native tissue ingrowth and remodeling. Abdominal wall tissues, including the linea alba (LA) and anterior rectus sheath (ARS), exhibit pronounced structural and mechanical heterogeneity that critically influences function and surgical outcomes. Current hernia repair meshes often fail to replicate this complexity, highlighting the need for a mechanistic understanding linking microarchitecture to tissue mechanics. This study combines uniaxial tensile testing with two-photon confocal microscopy to quantify collagen fiber orientation and elastin distribution in ARS and LA samples from eight human donors. Mechanical testing in longitudinal and transverse directions revealed pronounced anisotropy in ARS, with collagen alignment strongly predicting tissue stiffness (R 2 = 0.79–0.88) and explaining inter- and intra-individual mechanical variability. LA displayed a layered collagen network with higher elastin content, consistent with its role in strain accommodation. By directly correlating microstructural organization with mechanical performance, this work uncovers key design principles for bioinspired implants: anisotropic collagen fiber orientation and elastin distribution must be considered to replicate native tissue mechanics. Specifically, the findings demonstrate that replicating the anisotropic collagen–elastin architecture is essential for achieving biomechanical compatibility in surgical meshes. This study provides a novel framework for engineering heterogeneous materials that faithfully reproduce native tissue mechanics, bridging fundamental biomechanics and translational biomaterials design.

Authors

Publication Details

Journal
Materials & Design
Published
2025-09-27
DOI
https://doi.org/10.1016/j.matdes.2025.114853
Primary Topic
Hernia repair and management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microscopic characterization of the anisotropic mechanical behavior of human linea alba and anterior rectus sheath: contributions of collagen and elastin

Laure Astruc, Thierry Hoc, F. Turquier, Mathias Brieu
Materials & Design
Hernia repair and management
article

Microscopic characterization of the anisotropic mechanical behavior of human linea alba and anterior rectus sheath: contributions of collagen and elastin

Laure Astruc, Thierry Hoc, F. Turquier, Mathias Brieu
article en

Abstract

• The study focuses on the uniaxial mechanical properties of human linea alba and anterior rectus sheath with two-photon microscopy. • The anterior rectus sheath’s collagen fibers orientations strongly correlates with the tissue’s apparent stiffness. • Elastin is more abundant in the linea alba, consistent with its strain-accommodation role. • These findings support the design of patient-specific bioinspired implants replicating the mechanical conditions for native tissue ingrowth and remodeling. Abdominal wall tissues, including the linea alba (LA) and anterior rectus sheath (ARS), exhibit pronounced structural and mechanical heterogeneity that critically influences function and surgical outcomes. Current hernia repair meshes often fail to replicate this complexity, highlighting the need for a mechanistic understanding linking microarchitecture to tissue mechanics. This study combines uniaxial tensile testing with two-photon confocal microscopy to quantify collagen fiber orientation and elastin distribution in ARS and LA samples from eight human donors. Mechanical testing in longitudinal and transverse directions revealed pronounced anisotropy in ARS, with collagen alignment strongly predicting tissue stiffness (R 2 = 0.79–0.88) and explaining inter- and intra-individual mechanical variability. LA displayed a layered collagen network with higher elastin content, consistent with its role in strain accommodation. By directly correlating microstructural organization with mechanical performance, this work uncovers key design principles for bioinspired implants: anisotropic collagen fiber orientation and elastin distribution must be considered to replicate native tissue mechanics. Specifically, the findings demonstrate that replicating the anisotropic collagen–elastin architecture is essential for achieving biomechanical compatibility in surgical meshes. This study provides a novel framework for engineering heterogeneous materials that faithfully reproduce native tissue mechanics, bridging fundamental biomechanics and translational biomaterials design.

Materials & DesignVol. 259
Openalex Percentile: Top 58%
Hernia repair and management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Microscopic characterization of the anisotropic mechanical behavior of human linea alba and anterior rectus sheath: contributions of collagen and elastin — Laure Astruc, Thierry Hoc, et al. · Materials & Design (2025) | TGRS Research Map | TGRS