Development of a Side-View System for Atomic Force Microscopy (AFM)

This study presents the development of a side-view imaging system for atomic force microscopy (AFM). The system consists of a monochromatic camera, two lenses, a light source, and image processing software. Six qualitative tests were conducted to evaluate the system's field of view and resolution. The field of view tests used a target positioned both horizontally and vertically. In contrast, the high-resolution test was conducted with the target fixed horizontally and an exposure time of 3,000 milliseconds in both tests. The results allowed the evaluation of the optical system's performance. They demonstrated its feasibility for side imaging in the AFM system under development at the Optics Laboratory, ensuring greater precision in the probe's approach to the sample.

Authors

Publication Details

Journal
Journal of Bioengineering, Technologies and Health
Published
2025-09-12
DOI
https://doi.org/10.34178/jbth.v8i3.503
Primary Topic
Advanced Optical Sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Side-View System for Atomic Force Microscopy (AFM)

Valéria Loureiro da Silva, Marilena Meira, Valmara Silveira Ponte, Vitor Lucena Fabianski Campos
Journal of Bioengineering, Technologies and Health
Advanced Optical Sensing Technologies
article

Development of a Side-View System for Atomic Force Microscopy (AFM)

Valéria Loureiro da Silva, Marilena Meira, Valmara Silveira Ponte, Vitor Lucena Fabianski Campos
article en

Abstract

This study presents the development of a side-view imaging system for atomic force microscopy (AFM). The system consists of a monochromatic camera, two lenses, a light source, and image processing software. Six qualitative tests were conducted to evaluate the system's field of view and resolution. The field of view tests used a target positioned both horizontally and vertically. In contrast, the high-resolution test was conducted with the target fixed horizontally and an exposure time of 3,000 milliseconds in both tests. The results allowed the evaluation of the optical system's performance. They demonstrated its feasibility for side imaging in the AFM system under development at the Optics Laboratory, ensuring greater precision in the probe's approach to the sample.

Journal of Bioengineering, Technologies and HealthVol. 8(3)
SENAI CIMATEC, Fundação de Amparo à Pesquisa do Estado da Bahia
Openalex Percentile: Top 72%
Advanced Optical Sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.