A case study on optimizing helical tomotherapy parameters for small cell lung cancer with extensive pleural metastasis

The study aimed to evaluate the impact of various parameters on treatment plan quality and delivery time in helical tomotherapy (HT) for small cell lung cancer patients with extensive pleura metastasis (SCLC-EPM) and to identify the optimal parameter combination. Four SLCL-EPM patients were included. For each patient, the planning target volume (PTV) and organs at risk (OARs), including the left lung, right lung, total lung, heart, esophagus, spinal cord, were delineated. A total of 27 treatment plans per patient (108 total) were generated by varying three parameters: Field Width (FW), Pitch Factor (PF), Modulation Factor (MF). FW defined treatment field length at isocenter. Smaller FWs boosted precision but extend beam-on time. PF was couch movement per rotation relative to FW; tighter PFs reduced dose fluctuations; MF, the max-to-average leaf-opening ratio, improved modulation at the cost of longer delivery. The reference plan used default values (FW = 2.5 cm, PF = 0.287, MF = 3.6), assumed to yield the best dose distribution and treatment time. Plan quality was assessed using PTV metrics (Homogeneity index (HI), conformity index (CI), D<sub>95%</sub>, D<sub>90%</sub>, D<sub>2%</sub>), OAR metrics (Dmean, Dmax, V<sub>5Gy</sub>, V<sub>20Gy</sub>, V<sub>25Gy</sub>, V<sub>30Gy</sub>), and treatment time. FW significantly influenced dose distribution (particularly homogeneity, right lung, liver, and esophagus) and was the most critical parameter for reducing treatment time (average reduction > 50%). Tighter PF slightly decreased OARs dose (left lung, total lung, and live) without prolonging treatment time. Higher MF moderately increased treatment time and affected lung dose but showed no significant differences in CI or HI. Clinically, three patients achieved partial response, and one had stable disease at 6 months post-thoracic radiation, with no severe lung toxicities observed. Balancing plan quality and efficiency, the optimal HT parameters for SCLC-EPM were FW:2.5 cm, PF: 0.287, MF: 3. Radiotherapy for SCLC-EPM proved effective and safe after first-line chemotherapy with or without immunotherapy.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-09-29
DOI
https://doi.org/10.1038/s41598-025-18445-5
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A case study on optimizing helical tomotherapy parameters for small cell lung cancer with extensive pleural metastasis

Jiayi Chen, Chao Li, Wei-Xiang Qi, Longyan Duan et al.
Scientific Reports
Advanced Radiotherapy Techniques
article

A case study on optimizing helical tomotherapy parameters for small cell lung cancer with extensive pleural metastasis

Jiayi Chen, Chao Li, Wei-Xiang Qi, Longyan Duan, Shengguang Zhao
article en

Abstract

The study aimed to evaluate the impact of various parameters on treatment plan quality and delivery time in helical tomotherapy (HT) for small cell lung cancer patients with extensive pleura metastasis (SCLC-EPM) and to identify the optimal parameter combination. Four SLCL-EPM patients were included. For each patient, the planning target volume (PTV) and organs at risk (OARs), including the left lung, right lung, total lung, heart, esophagus, spinal cord, were delineated. A total of 27 treatment plans per patient (108 total) were generated by varying three parameters: Field Width (FW), Pitch Factor (PF), Modulation Factor (MF). FW defined treatment field length at isocenter. Smaller FWs boosted precision but extend beam-on time. PF was couch movement per rotation relative to FW; tighter PFs reduced dose fluctuations; MF, the max-to-average leaf-opening ratio, improved modulation at the cost of longer delivery. The reference plan used default values (FW = 2.5 cm, PF = 0.287, MF = 3.6), assumed to yield the best dose distribution and treatment time. Plan quality was assessed using PTV metrics (Homogeneity index (HI), conformity index (CI), D<sub>95%</sub>, D<sub>90%</sub>, D<sub>2%</sub>), OAR metrics (Dmean, Dmax, V<sub>5Gy</sub>, V<sub>20Gy</sub>, V<sub>25Gy</sub>, V<sub>30Gy</sub>), and treatment time. FW significantly influenced dose distribution (particularly homogeneity, right lung, liver, and esophagus) and was the most critical parameter for reducing treatment time (average reduction > 50%). Tighter PF slightly decreased OARs dose (left lung, total lung, and live) without prolonging treatment time. Higher MF moderately increased treatment time and affected lung dose but showed no significant differences in CI or HI. Clinically, three patients achieved partial response, and one had stable disease at 6 months post-thoracic radiation, with no severe lung toxicities observed. Balancing plan quality and efficiency, the optimal HT parameters for SCLC-EPM were FW:2.5 cm, PF: 0.287, MF: 3. Radiotherapy for SCLC-EPM proved effective and safe after first-line chemotherapy with or without immunotherapy.

Scientific ReportsVol. 15(1)
Ruijin Hospital (CN), Shanghai Genon Biological Products (China) (CN)
Shanghai Municipal Health Commission, Science and Technology Commission of Shanghai Municipality, Shanghai Hospital Development Center, Science and Technology Innovation Plan Of Shanghai Science and Technology Commission
Openalex Percentile: Top 64%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.