Laser Based Non-Invasive Blood Glucose Monitoring System

Abstract - Blood glucose monitoring (BGM) techniques are invasive as they require a finger prick blood sample, a repetitively painful process that creates the risk of infection. BGM is essential to avoid complications arising due to abnormal blood glucose levels in diabetic patients. Laser light-based sensors have demonstrated a superior potential for BGM. Existing near-infrared (NIR)-based BGM techniques have shortcomings, such as the absorption of light in human tissue, higher signal-to-noise ratio, and lower accuracy, and these disadvantages have prevented NIR techniques from being employed for commercial BGM applications. A simple, compact, and cost-effective non-invasive device using visible red laser light of wavelength 650 nm for BGM is implemented in this paper. The BGM monitoring device has three major technical advantages over NIR. Unlike NIR, red laser light has ~30 times better transmittance through human tissue. Furthermore, when compared with NIR, the refractive index of laser light is more sensitive to the variations in glucose level concentration resulting in faster response times ~7-10s. Red laser light also demonstrates both higher linearity and accuracy for BGM. Key Words: Red Laser, Non-invasive, 650nm, Better transmittance, Faster response time, Improved accuracy.

Authors

Publication Details

Journal
INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT
Published
2025-09-29
DOI
https://doi.org/10.55041/ijsrem52799
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Laser Based Non-Invasive Blood Glucose Monitoring System

M.S. Bhuvaneswari, Ms. P. Trisha, Mrs. A. Mohanadevi, M. Nithya
INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT
Spectroscopy Techniques in Biomedical and Chemical Research
article

Laser Based Non-Invasive Blood Glucose Monitoring System

M.S. Bhuvaneswari, Ms. P. Trisha, Mrs. A. Mohanadevi, M. Nithya
article en

Abstract

Abstract - Blood glucose monitoring (BGM) techniques are invasive as they require a finger prick blood sample, a repetitively painful process that creates the risk of infection. BGM is essential to avoid complications arising due to abnormal blood glucose levels in diabetic patients. Laser light-based sensors have demonstrated a superior potential for BGM. Existing near-infrared (NIR)-based BGM techniques have shortcomings, such as the absorption of light in human tissue, higher signal-to-noise ratio, and lower accuracy, and these disadvantages have prevented NIR techniques from being employed for commercial BGM applications. A simple, compact, and cost-effective non-invasive device using visible red laser light of wavelength 650 nm for BGM is implemented in this paper. The BGM monitoring device has three major technical advantages over NIR. Unlike NIR, red laser light has ~30 times better transmittance through human tissue. Furthermore, when compared with NIR, the refractive index of laser light is more sensitive to the variations in glucose level concentration resulting in faster response times ~7-10s. Red laser light also demonstrates both higher linearity and accuracy for BGM. Key Words: Red Laser, Non-invasive, 650nm, Better transmittance, Faster response time, Improved accuracy.

INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENTVol. 09(09)
Openalex Percentile: Top 81%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laser Based Non-Invasive Blood Glucose Monitoring System — M.S. Bhuvaneswari, Ms. P. Trisha, et al. · INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT (2025) | TGRS Research Map | TGRS