Comparison of single-dose and split-dose fecal tagging with iohexol in computed tomographic colonography

BACKGROUND: Proper fecal tagging allows for high-quality computed tomography colonography. However, there is no single tagging scheme. Therefore, the effects of a contrast enhancement regimen on fecal tagging should be evaluated. AIM: This study aimed to compare the quality of single-dose fecal tagging with that of split-dose fecal tagging with iohexol during computed tomographic colonography and to assess the impact of these regimens on procedure tolerability. METHODS: In this retrospective, selective, single-center study, the patients were divided into two groups based on whether they received single-dose (group 1) or split-dose (group 2) fecal tagging. Both groups received 50 mL of the iodine-containing contrast agent iohexol, with iodine concentration of 350 mg/mL. The residual liquid density was assessed using three parameters: maximum, minimum, and mean values. Additionally, the residual fluid homogeneity was assessed by calculating the mean standard deviation within the region of interest. Tolerability of preparation for colonography was assessed using a 10-point visual analog scale. RESULTS: The final sample included 338 patients: 116 in group 1 and 222 in group 2. The mean, minimum, and maximum density values in group 2 were significantly higher than those in group 1: 943 [722; 1245], 753 [525; 1082], and 1079 HU [801; 1456] versus 681 [420; 907], 570 [374; 820], and 825 HU [496; 1154], respectively (p 0.001). The residual fluid homogeneity was significantly higher in group 2 than in group 1: 59 [46; 78] versus 67 HU [54; 81] (р = 0.012). Group 2 showed a significantly lower subjective difficulty of preparation than did group 1: 4 [2; 6] and 5 [4; 7], respectively (p = 0.004). CONCLUSION: A single dose of 50 mL of iohexol (iodine concentration: 350 mg/mL) provides higher-quality fecal tagging than a split-dose provides because of higher residual fluid density with maintained homogeneity. Moreover, single-dose tagging was found to be more tolerable.

Authors

Institutions

Publication Details

Journal
Digital Diagnostics
Published
2025-09-12
DOI
https://doi.org/10.17816/dd633976
Primary Topic
Colorectal Cancer Screening and Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of single-dose and split-dose fecal tagging with iohexol in computed tomographic colonography

A. I. Meshcheryakov, Irina N. Kieva, O. G. Pugacheva, N. Yu. Gurova et al.
Digital Diagnostics
Colorectal Cancer Screening and Detection
article

Comparison of single-dose and split-dose fecal tagging with iohexol in computed tomographic colonography

A. I. Meshcheryakov, Irina N. Kieva, O. G. Pugacheva, N. Yu. Gurova, Alina V. Yakovleva, Ekaterina A. Kurmyshova
article en

Abstract

BACKGROUND: Proper fecal tagging allows for high-quality computed tomography colonography. However, there is no single tagging scheme. Therefore, the effects of a contrast enhancement regimen on fecal tagging should be evaluated. AIM: This study aimed to compare the quality of single-dose fecal tagging with that of split-dose fecal tagging with iohexol during computed tomographic colonography and to assess the impact of these regimens on procedure tolerability. METHODS: In this retrospective, selective, single-center study, the patients were divided into two groups based on whether they received single-dose (group 1) or split-dose (group 2) fecal tagging. Both groups received 50 mL of the iodine-containing contrast agent iohexol, with iodine concentration of 350 mg/mL. The residual liquid density was assessed using three parameters: maximum, minimum, and mean values. Additionally, the residual fluid homogeneity was assessed by calculating the mean standard deviation within the region of interest. Tolerability of preparation for colonography was assessed using a 10-point visual analog scale. RESULTS: The final sample included 338 patients: 116 in group 1 and 222 in group 2. The mean, minimum, and maximum density values in group 2 were significantly higher than those in group 1: 943 [722; 1245], 753 [525; 1082], and 1079 HU [801; 1456] versus 681 [420; 907], 570 [374; 820], and 825 HU [496; 1154], respectively (p 0.001). The residual fluid homogeneity was significantly higher in group 2 than in group 1: 59 [46; 78] versus 67 HU [54; 81] (р = 0.012). Group 2 showed a significantly lower subjective difficulty of preparation than did group 1: 4 [2; 6] and 5 [4; 7], respectively (p = 0.004). CONCLUSION: A single dose of 50 mL of iohexol (iodine concentration: 350 mg/mL) provides higher-quality fecal tagging than a split-dose provides because of higher residual fluid density with maintained homogeneity. Moreover, single-dose tagging was found to be more tolerable.

Digital DiagnosticsVol. 6(3)
Central Clinical Hospital and Polyclinic (RU), Presidential Executive Office (RU), Central State Medical Academy (RU), Ministry of Health of the Russian Federation (RU), Medical Radiological Research Center (RU), St. Petersburg State Medical Academy "City Polyclinic №44" (RU), P.A. Hertzen Moscow Oncology Research Institute (RU)
Openalex Percentile: Top 64%
Colorectal Cancer Screening and Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.