Comparative Effects of Fine and Conventional Shot Peening on Surface Morphology, Topography, Wettability, and Antibacterial Activity of Biomedical Ti6Al4V Alloy

Interest in textured surfaces for biomaterials and implants is increasing, with shot peening emerging as a promising method for surface modification. This study investigates the influence of conventional and fine shot peening on the surface morphology, topography, wettability, and antibacterial properties of biomedical-grade Ti6Al4V alloy. Peening was conducted using a custom-built, fully automated system, employing fine (100–200 µm) and coarse (700–1000 µm) shots using well-controlled sets of parameters. Both treatments introduced severe plastic deformation on the surface, resulting in increased roughness. Conventionally shot-peened samples exhibited deeper and wider dimples compared to finely peened ones. Surface wettability shifted from hydrophilic (contact angle: ~4°, untreated) to hydrophobic, reaching contact angles of ~91° and ~100° for fine and conventional shot peening, respectively. Antibacterial assays against Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) were evaluated by normalizing colony counts to the untreated Ti6Al4V surface. The inherent antibacterial response of Ti6Al4V against E. coli was preserved after both shot peening treatments, showing no notable increase in bacterial proliferation. In contrast, adhesion of S. aureus increased, more notably on fine shot-peened surfaces, indicating a strain-specific response influenced by surface roughness and wettability. In summary, both fine and conventional shot peening altered the surface morphology, topography, and wettability of Ti6Al4V. At the same time, their antibacterial influence was strain-dependent, underscoring the need for careful parameter selection in biomedical applications.

Authors

Institutions

Publication Details

Journal
Coatings
Published
2025-09-12
DOI
https://doi.org/10.3390/coatings15091071
Citations
1
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Effects of Fine and Conventional Shot Peening on Surface Morphology, Topography, Wettability, and Antibacterial Activity of Biomedical Ti6Al4V Alloy

Cagatay Elibol, Eray Abakay, Egemen Avcu, M. Wägner et al.
1 citations
Coatings
Bone Tissue Engineering Materials
0.67
article

Comparative Effects of Fine and Conventional Shot Peening on Surface Morphology, Topography, Wettability, and Antibacterial Activity of Biomedical Ti6Al4V Alloy

Cagatay Elibol, Eray Abakay, Egemen Avcu, M. Wägner, Rıdvan Yamanoğlu, Mine Sulak, Yasemin Yıldıran Avcu, M. Bahadir, Hüseyin Uzuner, Mustafa Armağan, Mert Güney
article en
1 citations

Abstract

Interest in textured surfaces for biomaterials and implants is increasing, with shot peening emerging as a promising method for surface modification. This study investigates the influence of conventional and fine shot peening on the surface morphology, topography, wettability, and antibacterial properties of biomedical-grade Ti6Al4V alloy. Peening was conducted using a custom-built, fully automated system, employing fine (100–200 µm) and coarse (700–1000 µm) shots using well-controlled sets of parameters. Both treatments introduced severe plastic deformation on the surface, resulting in increased roughness. Conventionally shot-peened samples exhibited deeper and wider dimples compared to finely peened ones. Surface wettability shifted from hydrophilic (contact angle: ~4°, untreated) to hydrophobic, reaching contact angles of ~91° and ~100° for fine and conventional shot peening, respectively. Antibacterial assays against Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) were evaluated by normalizing colony counts to the untreated Ti6Al4V surface. The inherent antibacterial response of Ti6Al4V against E. coli was preserved after both shot peening treatments, showing no notable increase in bacterial proliferation. In contrast, adhesion of S. aureus increased, more notably on fine shot-peened surfaces, indicating a strain-specific response influenced by surface roughness and wettability. In summary, both fine and conventional shot peening altered the surface morphology, topography, and wettability of Ti6Al4V. At the same time, their antibacterial influence was strain-dependent, underscoring the need for careful parameter selection in biomedical applications.

CoatingsVol. 15(9)
Sakarya University (TR), Chemnitz University of Technology (DE), Kocaeli Üniversitesi (TR), Istanbul Medeniyet University (TR), Nazarbayev University (KZ), Atatürk University (TR)
Openalex Percentile: Top 26%
Bone Tissue Engineering Materials
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.