Transforaminal “in-out-in” screw technique for posterior C2 fixation in cases with a narrow C2 pedicle: anatomical considerations, technical notes, and preliminary clinical results

Numerous techniques for C2 screw fixation have been recently reported. However, concerns remain regarding the risk of spinal cord or vertebral artery injury and inadequate biomechanical stability. To our knowledge, the specific transforaminal "in-out-in" screw fixation technique has not been previously reported. This study aimed to investigate the feasibility and preliminary clinical outcomes of a transforaminal "in-out-in" multi-cortical purchase screw for posterior C2 screw fixation. Between October 2022 and March 2023, 10 patients underwent posterior atlantoaxial internal fixation. All patients had severe hypoplasia of the C2 pedicle on at least one side, precluding the use of standard C2 pedicle screws. A transforaminal "in-out-in" screw was used as an alternative. No spinal cord injury, vascular injury, or other major complications were observed. No implant failure was noted at the final follow-up. In conclusion, the transforaminal "in-out-in" screw may achieve rigid three-column fixation with multiple cortical purchases. It represents a safe and effective alternative for posterior C2 fixation in patients with severely narrow C2 pedicles where traditional pedicle screw placement is not feasible.

Authors

Institutions

Publication Details

Journal
Asian Spine Journal
Published
2025-09-29
DOI
https://doi.org/10.31616/asj.2025.0160
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transforaminal “in-out-in” screw technique for posterior C2 fixation in cases with a narrow C2 pedicle: anatomical considerations, technical notes, and preliminary clinical results

Wubo Liu, Lei Qi, Cheng Qiu, Jun Yan
Asian Spine Journal
Spinal Fractures and Fixation Techniques
article

Transforaminal “in-out-in” screw technique for posterior C2 fixation in cases with a narrow C2 pedicle: anatomical considerations, technical notes, and preliminary clinical results

Wubo Liu, Lei Qi, Cheng Qiu, Jun Yan
article en

Abstract

Numerous techniques for C2 screw fixation have been recently reported. However, concerns remain regarding the risk of spinal cord or vertebral artery injury and inadequate biomechanical stability. To our knowledge, the specific transforaminal "in-out-in" screw fixation technique has not been previously reported. This study aimed to investigate the feasibility and preliminary clinical outcomes of a transforaminal "in-out-in" multi-cortical purchase screw for posterior C2 screw fixation. Between October 2022 and March 2023, 10 patients underwent posterior atlantoaxial internal fixation. All patients had severe hypoplasia of the C2 pedicle on at least one side, precluding the use of standard C2 pedicle screws. A transforaminal "in-out-in" screw was used as an alternative. No spinal cord injury, vascular injury, or other major complications were observed. No implant failure was noted at the final follow-up. In conclusion, the transforaminal "in-out-in" screw may achieve rigid three-column fixation with multiple cortical purchases. It represents a safe and effective alternative for posterior C2 fixation in patients with severely narrow C2 pedicles where traditional pedicle screw placement is not feasible.

Asian Spine JournalVol. 20(1)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking Union Medical College Hospital (CN), Qilu Hospital of Shandong University (CN)
Peking University, Peking University People's Hospital
Openalex Percentile: Top 58%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Transforaminal “in-out-in” screw technique for posterior C2 fixation in cases with a narrow C2 pedicle: anatomical considerations, technical notes, and preliminary clinical results — Wubo Liu, Lei Qi, et al. · Asian Spine Journal (2025) | TGRS Research Map | TGRS