Comparison of U.S. FDA Premarket Approval Studies Between Ray Tracing-Guided LASIK with InnovEyes Sightmap Versus Topography-Guided LASIK Using Custom Ablation Treatment (T-CAT)
While TG-LASIK showed superior visual acuity outcomes, RT-LASIK was associated with higher contrast sensitivity; however, both platforms demonstrate excellent visual and refractive outcomes. The majority of published studies are consistent with FDA PMA trends, showing potential reductions in spherical aberration and higher rates of 20/20 or better visual acuity with RT-LASIK.
Authors
- Phillip C. Hoopes (ORCID: https://orcid.org/0000-0002-2567-8331)
- Majid Moshirfar (ORCID: https://orcid.org/0000-0003-1024-6250)
- Mina M. Sitto (ORCID: https://orcid.org/0009-0001-4243-2499)
- T.J. Crook
Institutions
- University of Utah (US)
- Minnesota Lions Eye Bank (US)
- Hoopes Vision (US)
Publication Details
- Journal
- Ophthalmology and Therapy
- Published
- 2025-09-29
- DOI
- https://doi.org/10.1007/s40123-025-01245-5
- Citations
- 1
- Primary Topic
- Corneal surgery and disorders
- Type
- article
- Field-Weighted Citation Impact
- 1.36