A clinical case of implantation of a customized toric multifocal IOL Lentis Mplus LU-313T

Background. Modern cataract surgery requires increasingly high standards to achieve excellent visual outcomes at all distances, with mandatory intraoperative correction of corneal astigmatism. In such cases, customized intraocular lenses (IOLs), calculated according to the patient’s specific biometric parameters, are used. This report presents a clinical case of implanting a customized toric multifocal IOL during cataract surgery in a patient with high axial myopia and concomitant corneal astigmatism. Case description. A 45-year-old male with complicated cataract, high axial myopia, and corneal astigmatism underwent phacoemulsification with implantation of a customized multifocal IOL (Lentis Mplus LU-313T). In addition to standard ophthalmological examinations, optical specular endothelial microscopy of the cornea, optical coherence tomography (OCT) of the retina, and Scheimpflug corneal densitometry were performed. Preoperative IOL power calculation was carried out using an online calculator based on IOLMaster and corneal topography data. Postoperatively, uncorrected visual acuity was 1.0 for distance, 0.4 at intermediate, and 0.5 at near. Discussion. Implantation of customized IOLs with rotationally asymmetric optics, with a +2.0 D addition in the dominant right eye (Lentis Mplus LU-313 MF-20T) and a +3.0 D addition in the nondominant left eye (Lentis Mplus LU-313 MF-30TX), eliminated the need for postoperative optical correction at different distances. High uncorrected visual acuity was achieved for distance, intermediate, and near vision. The absence of halo effect after surgery enabled the patient to drive comfortably, including in the evening and at night. Conclusion. This comprehensive surgical approach to treating complicated cataract in eyes with high myopia and corneal astigmatism provided complete visual rehabilitation and eliminated the need for additional optical correction.

Authors

Institutions

Publication Details

Journal
The EYE GLAZ
Published
2025-09-28
DOI
https://doi.org/10.33791/2222-4408-2025-3-231-236
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A clinical case of implantation of a customized toric multifocal IOL Lentis Mplus LU-313T

Д. В. Перегудов, П. А. Перевозчиков, A.V. Solovey
The EYE GLAZ
Ocular Surface and Contact Lens
article

A clinical case of implantation of a customized toric multifocal IOL Lentis Mplus LU-313T

Д. В. Перегудов, П. А. Перевозчиков, A.V. Solovey
article en

Abstract

Background. Modern cataract surgery requires increasingly high standards to achieve excellent visual outcomes at all distances, with mandatory intraoperative correction of corneal astigmatism. In such cases, customized intraocular lenses (IOLs), calculated according to the patient’s specific biometric parameters, are used. This report presents a clinical case of implanting a customized toric multifocal IOL during cataract surgery in a patient with high axial myopia and concomitant corneal astigmatism. Case description. A 45-year-old male with complicated cataract, high axial myopia, and corneal astigmatism underwent phacoemulsification with implantation of a customized multifocal IOL (Lentis Mplus LU-313T). In addition to standard ophthalmological examinations, optical specular endothelial microscopy of the cornea, optical coherence tomography (OCT) of the retina, and Scheimpflug corneal densitometry were performed. Preoperative IOL power calculation was carried out using an online calculator based on IOLMaster and corneal topography data. Postoperatively, uncorrected visual acuity was 1.0 for distance, 0.4 at intermediate, and 0.5 at near. Discussion. Implantation of customized IOLs with rotationally asymmetric optics, with a +2.0 D addition in the dominant right eye (Lentis Mplus LU-313 MF-20T) and a +3.0 D addition in the nondominant left eye (Lentis Mplus LU-313 MF-30TX), eliminated the need for postoperative optical correction at different distances. High uncorrected visual acuity was achieved for distance, intermediate, and near vision. The absence of halo effect after surgery enabled the patient to drive comfortably, including in the evening and at night. Conclusion. This comprehensive surgical approach to treating complicated cataract in eyes with high myopia and corneal astigmatism provided complete visual rehabilitation and eliminated the need for additional optical correction.

The EYE GLAZVol. 27(3)
Polyclinic Medical Center (US), Expert System (Italy) (IT)
Openalex Percentile: Top 64%
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.