A Dynamic Monitoring System for The Thermal Conductivity of Transient Hot Wire Liquids

In this paper, the thermal conductivity measurement experimental setup built on the principle of transient short filament method was tested using liquid toluene, and the results indicated that the measurements from the experimental setup are accurate and reliable. The thermal conductivity of liquid n-dodecane was experimentally measured within the temperature range of 317.97K to 610.54K and the pressure range of 1MPa to 20MPa. The effective data from the measurements, ignoring the influence of radiation, were fitted into a function related to temperature and pressure. The experimental values were compared with the fitted values, and the relative deviations between the experimental values and the fitted values were found to be mostly within ±2%, with the maximum relative deviation being 2.6%.

Authors

Publication Details

Journal
Academic Journal of Science and Technology
Published
2025-09-27
DOI
https://doi.org/10.54097/9akjw147
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Dynamic Monitoring System for The Thermal Conductivity of Transient Hot Wire Liquids

Hao Zhao, Chun Yang, Xiaoting Qu, J. C. C. Fan et al.
Academic Journal of Science and Technology
Sensor Technology and Measurement Systems
article

A Dynamic Monitoring System for The Thermal Conductivity of Transient Hot Wire Liquids

Hao Zhao, Chun Yang, Xiaoting Qu, J. C. C. Fan, Y. H. Bian, Yihan Wang, Shuwei Yang
article en

Abstract

In this paper, the thermal conductivity measurement experimental setup built on the principle of transient short filament method was tested using liquid toluene, and the results indicated that the measurements from the experimental setup are accurate and reliable. The thermal conductivity of liquid n-dodecane was experimentally measured within the temperature range of 317.97K to 610.54K and the pressure range of 1MPa to 20MPa. The effective data from the measurements, ignoring the influence of radiation, were fitted into a function related to temperature and pressure. The experimental values were compared with the fitted values, and the relative deviations between the experimental values and the fitted values were found to be mostly within ±2%, with the maximum relative deviation being 2.6%.

Academic Journal of Science and TechnologyVol. 16(3)
Openalex Percentile: Top 69%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.